Literature DB >> 17326228

The release of nickel from orthodontic NiTi wires is increased by dynamic mechanical loading but not constrained by surface nitridation.

T Peitsch1, A Klocke, B Kahl-Nieke, O Prymak, M Epple.   

Abstract

The influence of dynamic mechanical loading and of surface nitridation on the nickel release from superelastic nickel-titanium orthodontic wires was investigated under ultrapure conditions. Commercially available superelastic NiTi arch wires (size 0.018 x 0.025'') without surface modification (Neo Sentalloy) and with nitrogen ion implantation surface treatment (Neo Sentalloy Ionguard) were analyzed. Mechanical loading of wire segments with a force similar to the physiological situation was performed with a frequency of 5 Hz in ultrapure water and saline solution, respectively. The release of nickel was monitored by atomic absorption spectroscopy for up to 36 days. The mechanically loaded wires released significantly more nickel ( approximately 45 ng cm(-2) d(-1)) than did nonloaded wires (<1 ng cm(-2) d(-1)). There was no statistically significant effect of the testing solution (water or NaCl) or of the surface nitridation. The total amount of released nickel was small in all cases, but may nevertheless account for the occasional clinical observations of adverse reactions during application of NiTi-based orthodontic appliances. The surface nitridation did not constrain the release of nickel from NiTi under continuous mechanical stress.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17326228     DOI: 10.1002/jbm.a.31097

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  4 in total

1.  Comparing Rotary Bend Wire Fatigue Test Methods at Different Test Speeds.

Authors:  Jason D Weaver; Erick J Gutierrez
Journal:  J Mater Eng Perform       Date:  2015-12       Impact factor: 1.819

2.  The release of nickel from nickel-titanium (NiTi) is strongly reduced by a sub-micrometer thin layer of calcium phosphate deposited by rf-magnetron sputtering.

Authors:  R A Surmenev; M A Ryabtseva; E V Shesterikov; V F Pichugin; T Peitsch; M Epple
Journal:  J Mater Sci Mater Med       Date:  2010-01-30       Impact factor: 3.896

3.  An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions' release following oral environment exposure.

Authors:  Abdul Razzak A Ghazal; Mohammad Y Hajeer; Rabab Al-Sabbagh; Ibrahim Alghoraibi; Ahmad Aldiry
Journal:  Prog Orthod       Date:  2015-05-20       Impact factor: 2.750

Review 4.  Biomedical Porous Shape Memory Alloys for Hard-Tissue Replacement Materials.

Authors:  Bin Yuan; Min Zhu; Chi Yuen Chung
Journal:  Materials (Basel)       Date:  2018-09-13       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.