Literature DB >> 17325507

Fluorescence dilution technique for measurement of cardiac output and circulating blood volume in healthy human subjects.

Jean-Michel I Maarek1, Daniel P Holschneider, Eduardo H Rubinstein.   

Abstract

BACKGROUND: The authors previously validated in an animal model a new indicator dilution technique for measuring cardiac output and circulating blood volume by recording transcutaneously the fluorescence of circulating indocyanine green with an optical probe placed on the skin surface. The current study compared fluorescence dilution recordings recorded from several locations on the human face in terms of signal intensity and stability and estimated the subjects' cardiac output and circulating blood volume from the recordings.
METHODS: Fluorescence dilution traces were recorded transcutaneously in six healthy human volunteers after rapid intravenous injection of 1 mg indocyanine green. Three placements of the optical probe were tested: the nose ala, the ear lobe, and the temple area. In three subjects, the recordings were calibrated in terms of circulating indocyanine green concentration to estimate cardiac output and circulating blood volume.
RESULTS: Fluorescence dilution traces had the same duration for the three locations, but the recordings obtained from the nose ala and the ear lobe were twice as intense as those from the temple. The fluorescence intensity at each site was linearly related to the local laser Doppler perfusion index. The coefficient of variation for the area under the first pass curve (inversely proportional to cardiac output) was approximately 6% for triplicate measurements at the same location. Cardiac output and circulating blood volume derived from the fluorescence recordings were in the normal range.
CONCLUSIONS: The study demonstrates that intense and reproducible fluorescence dilution signals can be measured transcutaneously in healthy humans and could potentially be used to measure cardiac output and circulating blood volume minimally invasively.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17325507     DOI: 10.1097/00000542-200703000-00013

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  5 in total

1.  Determination of renal function and injury using near-infrared fluorimetry in experimental cardiorenal syndrome.

Authors:  Mizuko Ikeda; Rumie Wakasaki; Katie J Schenning; Thomas Swide; Jeong Heon Lee; M Bernie Miller; Hak Soo Choi; Sharon Anderson; Michael P Hutchens
Journal:  Am J Physiol Renal Physiol       Date:  2017-01-11

2.  Evaluation of temperature-sensitive, indocyanine green-encapsulating micelles for noninvasive near-infrared tumor imaging.

Authors:  Tae Hee Kim; Yongping Chen; Christopher W Mount; Wayne R Gombotz; Xingde Li; Suzie H Pun
Journal:  Pharm Res       Date:  2010-06-22       Impact factor: 4.200

3.  Development and validation of quantitative optical index of skin blood content.

Authors:  Yu-Hao Peng; Jean-Michel I Maarek
Journal:  J Biomed Opt       Date:  2022-06       Impact factor: 3.758

Review 4.  PET Molecular Targets and Near-Infrared Fluorescence Imaging of Atherosclerosis.

Authors:  Csilla Celeng; Bart de Keizer; Béla Merkely; Pim de Jong; Tim Leiner; Richard A P Takx
Journal:  Curr Cardiol Rep       Date:  2018-02-12       Impact factor: 2.931

Review 5.  Progress of Phototherapy Applications in the Treatment of Bone Cancer.

Authors:  Jiachen Sun; Fei Xing; Joy Braun; Frank Traub; Pol Maria Rommens; Zhou Xiang; Ulrike Ritz
Journal:  Int J Mol Sci       Date:  2021-10-21       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.