Literature DB >> 17325144

Novel laser-activated solder for sealing corneal wounds.

Guillermo Noguera1, Woo-Seok Lee, Juan Castro-Combs, Roy S Chuck, Barbara Soltz, Robert Soltz, Ashley Behrens.   

Abstract

PURPOSE: To compare the effectiveness of a laser-activated biological tissue solder with that of standard sutures for sealing corneal incisions.
METHODS: Two keratome knives measuring either 3.0 mm or 2.85 mm were used to create a non-self-sealing peripheral oblique corneal wound (POCW) or a central perpendicular corneal wound (CPCW) in fresh rabbit cadaver eyes. Wounds were sealed with a solder strip (POCW; n = 5), a solder patch (CPCW; n = 5), or three interrupted nylon 10-0 sutures (n = 5). After the solder was placed on the wound, a diode laser was used to activate the solder, resulting in cross-linking to tissue. Wound stability was tested by a stepwise infusion of saline, and pressure changes were monitored with a digital manometer. Leaking pressure was recorded.
RESULTS: The pressurized mean baseline IOP in the intact globe was 131.13 mm Hg (SD, 4.66). Mean IOP after CPCW was 1.7 mm Hg (SD, 0.13); for POCW it was 3.62 mm Hg (SD, 3.09). For the CPCW group, the mean leaking pressure in the sutured eyes was 82.76 mm Hg (SD, 6.55), whereas in the solder patch it was 101.42 mm Hg (SD, 29.92; P = 0.2222). For the POCW group, the mean leaking pressure in the sutured eyes was 33.44 mm Hg (SD, 9.38), and the mean IOP achieved in the solder repaired eyes was 125.16 mm Hg (SD, 9.85; P = 0.0079).
CONCLUSIONS: The tested laser-activated solder was as effective as sutures when used as a patch and superior to sutures for clear corneal incisions in this animal ex vivo model.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17325144     DOI: 10.1167/iovs.06-0488

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  5 in total

1.  High intensity focused ultrasound as a tool for tissue engineering: Application to cartilage.

Authors:  Adam B Nover; Gary Y Hou; Yang Han; Shutao Wang; Grace D O'Connell; Gerard A Ateshian; Elisa E Konofagou; Clark T Hung
Journal:  Med Eng Phys       Date:  2015-12-24       Impact factor: 2.242

2.  Corneal cut closure using temperature-controlled CO2 laser soldering system.

Authors:  Kfir Tal; Eyal Strassmann; Nino Loya; Avi Ravid; Noam Kariv; Dov Weinberger; Abraham Katzir; Dan D Gaton
Journal:  Lasers Med Sci       Date:  2015-03-22       Impact factor: 3.161

Review 3.  Cataract surgery and methods of wound closure: a review.

Authors:  Cynthia Matossian; Sarah Makari; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-05-22

Review 4.  Clear corneal incision in cataract surgery.

Authors:  Ammar M Al Mahmood; Samar A Al-Swailem; Ashley Behrens
Journal:  Middle East Afr J Ophthalmol       Date:  2014 Jan-Mar

5.  In Vitro Feasibility Analysis of a New Sutureless Wound-Closure System Based on a Temperature-Regulated Laser and a Transparent Collagen Membrane for Laser Tissue Soldering (LTS).

Authors:  Moritz Alexander Birkelbach; Ralf Smeets; Imke Fiedler; Lan Kluwe; Martin Wehner; Tilmann Trebst; Philip Hartjen
Journal:  Int J Mol Sci       Date:  2020-09-26       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.