BACKGROUND: The tensile strength of running monofilament polypropylene sutures anchored with square knots was compared with the strength of the same size sutures anchored with half hitches. STUDY
DESIGN: Polypropylene (Prolene; Ethicon) 0, 2-0, 3-0, 4-0, and 5-0 sutures were secured to a tensionometer with either square knots or half hitches. As tension was applied to the running suture end, the force required to break the suture and the point at which the break occurred were recorded.
RESULTS: The sutures anchored with square knots showed only 75% of the strength of the sutures secured with half hitches (p=<0.001). Every suture tied with square knots broke precisely at the point where the last two squared throws invariably tumbled into half hitches with increased tension on the running end. The resulting stress transformation distorted and weakened the suture, as documented by electron microscopy scanning. The sutures secured with half hitches did not show any surface defects, and none of the running sutures tied down with half hitches broke at the knots.
CONCLUSIONS: A running polypropylene suture initially anchored with half hitches is stronger and safer than a running suture tied down with square knots.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17324776     DOI: 10.1016/j.jamcollsurg.2006.12.024

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  4 in total

1.  Variability of surgical knot tying techniques: do we need to standardize?

Authors:  Lars Fischer; Thomas Bruckner; Beat P Müller-Stich; Jörg Höer; Hanns-Peter Knaebel; Markus W Büchler; Christoph M Seiler
Journal:  Langenbecks Arch Surg       Date:  2009-12-16       Impact factor: 3.445

2.  Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.

Authors:  Xytilis Avoine; Bertrand Lussier; Vladimir Brailovski; Karine Inaekyan; Guy Beauchamp
Journal:  Can J Vet Res       Date:  2016-04       Impact factor: 1.310

3.  Parallel alternating sliding knots are effective for ligation of mesenteric arteries during resection and anastomosis of the equine jejunum.

Authors:  Marco Gandini; Gessica Giusto; Francesco Comino; Eleonora Pagliara
Journal:  BMC Vet Res       Date:  2014-07-07       Impact factor: 2.741

4.  BioGlue® is not associated with polypropylene suture breakage after aortic surgery.

Authors:  Davide Pacini; Giacomo Murana; David Hollinworth; William F Northrup; Stacy G Arnold; Roberto Di Bartolomeo
Journal:  Front Surg       Date:  2022-09-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.