Literature DB >> 17324642

A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the estimation of bisoprolol in human plasma using multiplexing technique.

Jignesh Bhatt1, Gunta Subbaiah, Sandeep Kambli, Bhavin Shah, Mehul Patel, Ashish Saxena, Ashok Baliga, Samita Nigam, Hetal Parekh, Gunvat Yadav.   

Abstract

A high throughput and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of bisoprolol in human plasma using multiplexing technique (two HPLC units connected to one MS). Bisoprolol was extracted from human plasma using solid-phase extraction technique using metoprolol as internal standard. A Betabasic 8 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 326.2-->116.1 for bisoprolol and m/z 268.2-->191.0 for metoprolol. The method involves a simple multiplexing, rapid solid-phase extraction, simple isocratic chromatography conditions and mass spectrometric detection which enable detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.5-70.0 ng/mL with correlation coefficient > or =0.9991. The precision and accuracy were within 10% for intra-HPLC runs and inter-HPLC runs. The overall recoveries for bisoprolol and metoprolol were 93.89% and 77.65%, respectively. Total MS run time was 0.90 min only. The developed method was applied for the determination of pharmacokinetic parameters of bisoprolol following a single oral administration of a 10mg bisoprolol tablet in 18 healthy male volunteers.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17324642     DOI: 10.1016/j.jchromb.2007.01.043

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  2 in total

1.  A new liquid chromatography-tandem mass spectrometry method for determination of bisoprolol in human plasma samples.

Authors:  Gabriela Peste; Nela Bibire; Mihai Apostu; Aurel Vlase; Corneliu Oniscu
Journal:  J Biomed Biotechnol       Date:  2009-08-19

2.  Bioequivalence study of two formulations of bisoprolol fumarate film-coated tablets in healthy subjects.

Authors:  Raymond R Tjandrawinata; Effi Setiawati; Danang Agung Yunaidi; Iwan Dwi Santoso; Arini Setiawati; Liana W Susanto
Journal:  Drug Des Devel Ther       Date:  2012-10-30       Impact factor: 4.162

  2 in total