Literature DB >> 1732269

The histology of the radiolucent line.

L M Kwong1, M Jasty, R D Mulroy, W J Maloney, C Bragdon, W H Harris.   

Abstract

The radiographic and histological features of radiolucent areas at the cement-bone interface were correlated in 15 specimens retrieved at post-mortem from patients who had undergone cemented total hip arthroplasty, two weeks to 15 years prior to death. All but one of the components were securely fixed, as demonstrated by direct measurements of micromotion. Extensive radiolucencies were present in all but one case. In 11 of the 14 specimens with radiolucencies, histological examination showed that the radiolucent areas represented regions of osteoporosis and bone remodelling. The remodelling changes were characterised by osteoporosis, cancellisation and thinning of the endosteal cortex, and osteopenia of the trabecular bone. In two specimens the appearance of radiolucency was found to be due to fibrous tissue at the cement-bone interface and in one specimen there was a mixed picture of osteolysis and fibrosis. The study demonstrates that radiolucent lines can occur with well-fixed components and that they may commonly represent osteoporosis rather than the presence of a fibrous membrane at the cement-bone interface.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1732269

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Prospective, comparative study of cemented, smooth-surfaced titanium stems and polish-surfaced, stainless steel stems at a minimum follow-up of 10 years.

Authors:  Hiroshi Fujita; Hiroaki Hara; Hideto Harada; Masanao Kataoka; Tomohiro Tominaga; Ryuuichi Nishimura
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-18

2.  A new approach to quantify trabecular resorption adjacent to cemented knee arthroplasty.

Authors:  Kenneth A Mann; Mark A Miller; Caitlin L Pray; Nico Verdonschot; Dennis Janssen
Journal:  J Biomech       Date:  2012-01-09       Impact factor: 2.712

Review 3.  Particle disease: biologic mechanisms of periprosthetic osteolysis in total hip arthroplasty.

Authors:  Jiri Gallo; Stuart B Goodman; Yrjö T Konttinen; Milan Raska
Journal:  Innate Immun       Date:  2012-06-29       Impact factor: 2.680

4.  Femoral remodeling around Charnley total hip arthroplasty is unpredictable.

Authors:  Matthew J Teusink; Katharine A Callaghan; Noelle F Klocke; Devon D Goetz; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

5.  Effect of particles and interface conditions on fibrous tissue interposition between bone and implant. A particle challenge model in rabbit.

Authors:  H Ohashi; A Kobayashi; Y Kadoya; Y Yamano; H Oonishi; H Iwaki
Journal:  J Mater Sci Mater Med       Date:  2000-04       Impact factor: 3.896

6.  Shear fatigue micromechanics of the cement-bone interface: An in vitro study using digital image correlation techniques.

Authors:  Kenneth A Mann; Mark A Miller; Amos Race; Nico Verdonschot
Journal:  J Orthop Res       Date:  2009-03       Impact factor: 3.494

  6 in total