Literature DB >> 17321530

High-throughput on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of 14 antidepressants and their metabolites in plasma.

Ana de Castro1, Maria del Mar Ramírez Fernandez, Marleen Laloup, Nele Samyn, Gert De Boeck, Michelle Wood, Viviane Maes, Manuel López-Rivadulla.   

Abstract

A rapid, sensitive and fully automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method was developed and validated for the direct analysis of 14 antidepressants and their metabolites in plasma. Integration of the sample extraction and LC separation into a single system permitted direct injection of the plasma without prior sample pre-treatment. The applied gradient ensured the elution of all the examined drugs within 14 min and produced chromatographic peaks of acceptable symmetry. The total process time was 20 min and only 50 microL of plasma was required. Selectivity of the method was achieved by a combination of retention time and two precursor-product ion transitions for the non-deuterated compounds. The use of SPE was demonstrated to be highly effective and led to significant decreases in the interferences present in the matrix. Extraction was found to be both reproducible and efficient with recoveries >99% for all the analytes. The method showed excellent intra-assay and inter-assay precision (relative standard deviation (RSD) and bias <20%) for quality control (QC) samples spiked at a concentration of 40, 200 and 800 microg/L and the r2>0.99 over the range investigated (10-1000 microg/L). Limits of quantification (LOQs) were estimated to be 10 microg/L. Furthermore, the processed samples were demonstrated to be stable for at least 48 h, except for clomipramine and norclomipramine, where a slight negative trend was observed, but did not compromise the quantification. The method was subsequently applied to authentic samples previously screened by a routine HPLC method with diode array detection (DAD).

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17321530     DOI: 10.1016/j.chroma.2007.01.137

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Occurrence and risk assessment of antidepressants in Huangpu River of Shanghai, China.

Authors:  Minghong Wu; Jiajia Xiang; Fenfen Chen; Cao Fu; Gang Xu
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-13       Impact factor: 4.223

2.  A Simple, Rapid and Reliable Method to Determine Imipramine and Desipramine in Mouse Serum Using Ultra-High-Performance Liquid Chromatography-Quadrupole-Time-of-Flight Mass Spectrometry.

Authors:  Jing Zhao; Yujin Shin; Kwang-Hoon Chun; Hye-Ran Yoon; Jeongmi Lee
Journal:  J Chromatogr Sci       Date:  2015-12-19       Impact factor: 1.618

3.  Gelatin microsphere coated Fe3O4@graphene quantum dots nanoparticles as a novel magnetic sorbent for ultrasound-assisted dispersive magnetic solid-phase extraction of tricyclic antidepressants in biological samples.

Authors:  Zolfaghar Aladaghlo; Siamak Javanbakht; Ali Reza Fakhari; Ahmad Shaabani
Journal:  Mikrochim Acta       Date:  2021-02-06       Impact factor: 6.408

4.  Determination of Antidepressants in Human Plasma by Modified Cloud-Point Extraction Coupled with Mass Spectrometry.

Authors:  Elżbieta Gniazdowska; Natalia Korytowska; Grzegorz Kłudka; Joanna Giebułtowicz
Journal:  Pharmaceuticals (Basel)       Date:  2020-12-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.