Literature DB >> 17320427

In vivo comparison of the biocompatibility of two root canal sealers implanted into the subcutaneous connective tissue of rats.

Edilson José Zafalon1, Marco Aurélio Versiani, Cássio José Alves de Souza, Camila Christian Gomes Moura, Paula Dechichi.   

Abstract

OBJECTIVE: To evaluate the subcutaneous biocompatibility of 2 root canal sealers. STUDY
DESIGN: The subcutaneous implant technique recommended by the Fédération Dentaire International (FDI) was used to test Endométhasone and EndoREZ root canal sealers. These materials were placed in Teflon tubes, 1 mm in diameter and 10 mm in length, and implanted into 2 pockets created in the back of 40 Calomys callosus rodents, 20 for each material. Tissue biopsies were collected and histologically examined 15, 30, 60, and 90 days after the implantation procedure. The overall level of the inflammatory tissue response was graded as none, slight, moderate, or severe on the sealer-connective tissue interface at the opening ends of the tubes. The connective tissue response along the lateral wall outside of each tube served as a negative control.
RESULTS: The tissue reaction to the Endométhasone diminished with time. The EndoREZ sealer was highly toxic during all experimental periods.
CONCLUSION: Endométhasone root canal sealer presented biocompatibility within the analyzed periods, whereas EndoREZ showed no biocompatible behavior and caused late hypersensitive reaction.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17320427     DOI: 10.1016/j.tripleo.2006.11.025

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  5 in total

1.  Investigating unset endodontic sealers' eugenol and hydrocortisone roles in modulating the initial steps of inflammation.

Authors:  Charlotte Jeanneau; Thomas Giraud; Jean-Louis Milan; Imad About
Journal:  Clin Oral Investig       Date:  2019-05-21       Impact factor: 3.573

2.  A study on biocompatibility of three endodontic sealers: intensity and duration of tissue irritation.

Authors:  Camilla Christian Gomes Moura; Thais Cristina Cunha; Virgínia Oliveira Crema; Paula Dechichi; João Carlos Gabrielli Biffi
Journal:  Iran Endod J       Date:  2014-03-08

3.  Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model.

Authors:  Salma Omidi; Maryam Javidi; Mina Zarei; Siavash Mushakhian; Amirhossein Jafarian
Journal:  Iran Endod J       Date:  2017

Review 4.  Biocompatibility of Root Canal Sealers: A Systematic Review of In Vitro and In Vivo Studies.

Authors:  Diogo Afonso Fonseca; Anabela Baptista Paula; Carlos Miguel Marto; Ana Coelho; Siri Paulo; José Pedro Martinho; Eunice Carrilho; Manuel Marques Ferreira
Journal:  Materials (Basel)       Date:  2019-12-09       Impact factor: 3.623

5.  The evaluation of cytotoxicity and cytokine IL-6 production of root canal sealers with and without the incorporation of simvastatin: an invitro study.

Authors:  Apoorva Sharma; Kavitha Sanjeev; Vinola M J Selvanathan; Mahalaxmi Sekar; Nikhil Harikrishnan
Journal:  BMC Oral Health       Date:  2022-01-11       Impact factor: 2.757

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.