Literature DB >> 17320373

Nanowire labeled direct-charge transfer biosensor for detecting Bacillus species.

Sudeshna Pal1, Evangelyn C Alocilja, Frances P Downes.   

Abstract

A direct-charge transfer (DCT) biosensor was developed for the detection of the foodborne pathogen, Bacillus cereus. The biosensor was fabricated using antibodies as the sensing element and polyaniline nanowire as the molecular electrical transducer. The sensor design consisted of four membrane pads, namely, sample application, conjugate, capture and absorption pads. Two sets of polyclonal antibodies, secondary antibodies conjugated with polyaniline nanowires and capture antibodies were applied to the conjugate and the capture pads of the biosensor, respectively. The detection technique was based on capillary flow action which allowed the liquid sample to move from one membrane to another. The working principle involved antigen-antibody interaction and direct electron charge flow to generate a resistance signal that was being recorded. Detection from sample application to final results was completed in 6 min in a reagentless process. Experiments were conducted to find the best performance of the biosensors by varying polyaniline types and concentrations. Polyaniline protonated with hydrochloric acid, emeraldine salt and polyaniline protonated with perchloric acid were the three kinds of polyaniline used in this study. The biosensor sensitivity in pure cultures of B. cereus was found to be 10(1) to 10(2)CFU/ml. Results indicated that using emeraldine salt at a concentration of 0.25 g/ml gave the best biosensor performance in terms of sensitivity. The biosensor was also found to be specific in detecting the presence of B. cereus in a mixed culture of different Bacillus species and other foodborne pathogens. The speed, sensitivity and ease-of-use of this biosensor make it a promising device for rapid field-based diagnosis towards the protection of our food supply chain. The phenotypic and genotypic similarities between B. cereus and Bacillus anthracis will also allow this biosensor to serve as an excellent model for the detection of B. anthracis.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17320373     DOI: 10.1016/j.bios.2007.01.013

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  20 in total

Review 1.  Nanoparticles as biochemical sensors.

Authors:  Afaf El-Ansary; Layla M Faddah
Journal:  Nanotechnol Sci Appl       Date:  2010-09-23

2.  Targeted cell detection based on microchannel gating.

Authors:  Mehdi Javanmard; Amirali H Talasaz; Mohsen Nemat-Gorgani; Fabian Pease; Mostafa Ronaghi; Ronald W Davis
Journal:  Biomicrofluidics       Date:  2007-11-30       Impact factor: 2.800

3.  A novel and highly specific phage endolysin cell wall binding domain for detection of Bacillus cereus.

Authors:  Minsuk Kong; Jieun Sim; Taejoon Kang; Hoang Hiep Nguyen; Hyun Kyu Park; Bong Hyun Chung; Sangryeol Ryu
Journal:  Eur Biophys J       Date:  2015-06-05       Impact factor: 1.733

4.  Implications of limits of detection of various methods for Bacillus anthracis in computing risks to human health.

Authors:  Amanda B Herzog; S Devin McLennan; Alok K Pandey; Charles P Gerba; Charles N Haas; Joan B Rose; Syed A Hashsham
Journal:  Appl Environ Microbiol       Date:  2009-07-31       Impact factor: 4.792

Review 5.  Interfacial structures and properties of organic materials for biosensors: an overview.

Authors:  Yan Zhou; Cheng-Wei Chiu; Hong Liang
Journal:  Sensors (Basel)       Date:  2012-11-06       Impact factor: 3.576

6.  Fabrication of a Novel Conductometric Biosensor for Detecting Mycobacterium avium subsp. paratuberculosis Antibodies.

Authors:  Chika Okafor; Daniel Grooms; Evangelyn Alocilja; Steven Bolin
Journal:  Sensors (Basel)       Date:  2008-09-26       Impact factor: 3.576

7.  Nucleic Acid-based Detection of Bacterial Pathogens Using Integrated Microfluidic Platform Systems.

Authors:  Clarissa Lui; Nathaniel C Cady; Carl A Batt
Journal:  Sensors (Basel)       Date:  2009-05-18       Impact factor: 3.576

8.  Microfluidic systems for pathogen sensing: a review.

Authors:  Jürgen Mairhofer; Kriemhilt Roppert; Peter Ertl
Journal:  Sensors (Basel)       Date:  2009-06-17       Impact factor: 3.576

9.  An overview of recent strategies in pathogen sensing.

Authors:  Jinseok Heo; Susan Z Hua
Journal:  Sensors (Basel)       Date:  2009-06-08       Impact factor: 3.576

10.  Detection of non-PCR amplified S. enteritidis genomic DNA from food matrices using a gold-nanoparticle DNA biosensor: a proof-of-concept study.

Authors:  Sylvia A Vetrone; Michael C Huarng; Evangelyn C Alocilja
Journal:  Sensors (Basel)       Date:  2012-08-02       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.