Literature DB >> 17319180

Mini dental implants for long-term fixed and removable prosthetics: a retrospective analysis of 2514 implants placed over a five-year period.

Todd E Shatkin1, Samuel Shatkin, Benjamin D Oppenheimer, Adam J Oppenheimer.   

Abstract

Over the past decade, endosseous implants of increasingly smaller diameters have been introduced into the field of dentistry. Small diameter implants (SDIs) are generally 2.75 mm to 3.3 mm in diameter. They are frequently used in cases of limited alveolar anatomy Mini dental implants (MDIs) are smaller than their SDI counterparts, with diameters ranging from 1.8 mm to 2.4 mm. They are suitable for long-term use-a task for which the device was approved by the Food and Drug Administration. The following study describes the authors' experience with MDIs under this indication. Over a 5-year period, 2514 MDIs were placed in 531 patients. The mean duration of follow-up was 2.9 years. The implants supported fixed (1278) and removable prostheses (1236), with nearly equal placement in the mandible and maxilla (1256 and 1258, respectively). The overall implant survival was 94.2%. Based on a Cox proportional hazards model, statistically significant predictors of failure include use in removable prostheses (hazard ratio = 4.28), the posterior maxilla (3.37), atrophic bone (3.32), and cigarette smokers (2.28). Implant failures (145) were attributed to mobility with or without suppuration (19% vs 81%, respectively). The mean failure time for these implants was approximately 6.4 months (193+/-42 days). This temporally correlates with the osseointegration period. A learning curve was established for this procedure, and implant survival improved with placement experience. Based on these results, the authors have devised treatment guidelines for the use of MDIs in long-term fixed and removable prostheses. MDIs are not a panacea; however, proper training enables the general dentist to successfully implement MDIs into clinical practice.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17319180

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  6 in total

1.  Predictable aesthetic outcome with immediate placement and early loading of one piece mini implant - A 5 year follow-up case report.

Authors:  C S Anand Mohan; P Harinath; Priyanka K Cholan; D Lokesh Kumar
Journal:  J Int Oral Health       Date:  2014-04-26

2.  Geriatric slim implants for complete denture wearers: clinical aspects and perspectives.

Authors:  Cedric Huard; Marion Bessadet; Emmanuel Nicolas; Jean-Luc Veyrune
Journal:  Clin Cosmet Investig Dent       Date:  2013-08-28

3.  Customized SmartPeg for measurement of resonance frequency of mini dental implants.

Authors:  Jagjit Singh Dhaliwal; Rubens F Albuquerque; Ali Fakhry; Sukhbir Kaur; Jocelyne S Feine
Journal:  Int J Implant Dent       Date:  2017-02-01

4.  A pilot randomised controlled trial evaluating mini and conventional implant retained dentures on the function and quality of life of patients with an edentulous mandible.

Authors:  Sarra Jawad; Craig Barclay; William Whittaker; Martin Tickle; Tanya Walsh
Journal:  BMC Oral Health       Date:  2017-02-15       Impact factor: 2.757

5.  Osseointegration of standard and mini dental implants: a histomorphometric comparison.

Authors:  Jagjit S Dhaliwal; Rubens F Albuquerque; Monzur Murshed; Jocelyne S Feine
Journal:  Int J Implant Dent       Date:  2017-05-01

6.  Dental Trauma Management in a Young Teenager through Endodontics and Implantology: A Case Report.

Authors:  Marie-Laure Munoz-Sanchez; Nicolas Decerle; Laurent Devoize; Emmanuel Nicolas; Pierre-Yves Cousson; Jean-Luc Veyrune
Journal:  Healthcare (Basel)       Date:  2021-05-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.