Literature DB >> 17318690

Laparoscopic spray application of fibrin sealant effects on hemodynamics and spray efficiency at various application pressures and distances.

K T Druckrey-Fiskaaen1, M W W Janssen, L Omidi, N Polze, U Kaisers, I Nur, E Goldberg, G Bokel, J Hauss, Michael R Schön.   

Abstract

BACKGROUND: Laparoscopic resections of parenchymal organs are increasingly performed. However, little is known about the effects of laparoscopic fibrin sealant spray applications on intraabdominal pressure (IAP) and hemodynamics.
METHODS: Cardiac and pulmonary monitoring was performed via two central venous pressure lines in the thoracic and abdominal vena cava, a pulmonary artery catheter, and a peripheral artery line. Air was sprayed into the abdomen at pressures of 2, 3, and 4 bar for 30 s. According to the group, a valve on a trocar was open or closed. To optimize fibrin sealant application, the sealant was sprayed at three different application pressures (2, 2.5, and 3 bar) and distances (2, 3.5, and 5 cm).
RESULTS: All spray simulations caused a significant increase in the IAP. During the first 10 s of spraying, the IAP increase was 5 mmHg or less, but rose rapidly during the last 20 s of spraying. The IAP increase resulted in decreased pulmonary compliance. Pulmonary resistance and the central venous pressures of both the thoracic and abdominal vena cava increased. At application pressures of 3 and 4 bar, the IAP increase was greater than 2 bar of pressure, reaching IAP values exceeding 35 mmHg. Spray mist formation was primarily dependent on application pressure, whereas clot formation and surface coverage depended on both application pressure and distance. The best results were achieved with an application pressure of 2.5 bar and a distance of 5 cm from the surface.
CONCLUSIONS: This study shows that fibrin sealants can be used safely in laparoscopic procedures. Keeping the spray periods short and allowing air to escape from the abdomen can minimize the IAP increase. According to our results, a laparoscopic spray application of fibrin sealant should start with an insufflation pressure of 10 mmHg, an application pressure of 2.5 bar, and an application distance of 5 cm with a valve on the trocar left open.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17318690     DOI: 10.1007/s00464-007-9235-7

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  27 in total

Review 1.  Fibrin sealants in surgical practice: An overview.

Authors:  M R Jackson
Journal:  Am J Surg       Date:  2001-08       Impact factor: 2.565

2.  Transoesophageal echocardiography shows high risk of gas embolism during laparoscopic hepatic resection under carbon dioxide pneumoperitoneum.

Authors:  T C Schmandra; S Mierdl; H Bauer; C Gutt; E Hanisch
Journal:  Br J Surg       Date:  2002-07       Impact factor: 6.939

3.  An increase of abdominal pressure increases pulmonary edema in oleic acid-induced lung injury.

Authors:  Michael Quintel; Paolo Pelosi; Pietro Caironi; Jurgen Peter Meinhardt; Thomas Luecke; Peter Herrmann; Paolo Taccone; Christian Rylander; Franco Valenza; Eleonora Carlesso; Luciano Gattinoni
Journal:  Am J Respir Crit Care Med       Date:  2003-12-11       Impact factor: 21.405

4.  Laparoscopic liver resection.

Authors:  D Cherqui
Journal:  Br J Surg       Date:  2003-06       Impact factor: 6.939

Review 5.  New hemostatic agents in general open and laparoscopic surgery.

Authors:  Namir Katkhouda
Journal:  Surg Technol Int       Date:  2004

6.  The effects of elevated intraabdominal pressure, hypercarbia, and positioning on the hemodynamic responses to laparoscopic colectomy in pigs.

Authors:  K D Horvath; R L Whelan; B Lier; S Viscomi; L Barry; K Buck; M Bessler
Journal:  Surg Endosc       Date:  1998-02       Impact factor: 4.584

Review 7.  Physiologic changes during laparoscopy.

Authors:  C O'Malley; A J Cunningham
Journal:  Anesthesiol Clin North Am       Date:  2001-03

Review 8.  The physiologic effects of pneumoperitoneum in the morbidly obese.

Authors:  Ninh T Nguyen; Bruce M Wolfe
Journal:  Ann Surg       Date:  2005-02       Impact factor: 12.969

Review 9.  Systematic review of the use of fibrin sealant to minimize perioperative allogeneic blood transfusion.

Authors:  P A Carless; D M Anthony; D A Henry
Journal:  Br J Surg       Date:  2002-06       Impact factor: 6.939

10.  The use of a fibrin tissue sealant during laparoscopic partial nephrectomy.

Authors:  R S Pruthi; J Chun; M Richman
Journal:  BJU Int       Date:  2004-04       Impact factor: 5.588

View more
  4 in total

Review 1.  [Value of laparoscopic liver resection].

Authors:  M R Schön
Journal:  Chirurg       Date:  2010-06       Impact factor: 0.955

2.  Description of a novel approach for intraperitoneal drug delivery and the related device.

Authors:  Wiebke Solaß; Alexander Hetzel; Giorgi Nadiradze; Emil Sagynaliev; Marc A Reymond
Journal:  Surg Endosc       Date:  2012-05-12       Impact factor: 4.584

3.  Nitrogenous subcutaneous emphysema caused by spray application of fibrin glue during retroperitoneal laparoscopic surgery.

Authors:  Shinji Matsuse; Atsushi Maruyama; Yoshiki Hara
Journal:  J Anesth       Date:  2011-03-22       Impact factor: 2.078

Review 4.  Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive-a Laboratory and Clinical Perspective.

Authors:  William D Spotnitz
Journal:  ISRN Surg       Date:  2014-03-04
  4 in total