Comparison of effectiveness of bare metal stents versus drug-eluting stents in large (> or =3.5 mm) coronary arteries.

Daniel H Steinberg1, Sundeep Mishra, Aamir Javaid, Tina L Pinto Slottow, Ashesh N Buch, Probal Roy, Teruo Okabe, Kimberly A Smith, Rebecca Torguson, Zhenyi Xue, Augusto D Pichard, Lowell F Satler, Kenneth M Kent, William O Suddath, Ron Waksman.   

Abstract

Drug-eluting stents (DESs) are superior to bare metal stents (BMSs) in decreasing restenosis rates across a wide range of patient and lesion subsets. However, widespread utilization of DESs raises concerns with regard to risks of prolonged dual antiplatelet therapy, the potential for late adverse events such as late thrombosis, and cost. Vessel diameter and lesion length have been previously identified as predictors for restenosis for DESs and BMSs. This study compared the clinical outcomes of DESs versus BMSs in large coronary arteries (> or =3.5 mm). A cohort of 233 patients who underwent single-vessel angioplasty with DES implantation in large vessels was compared with 233 propensity-matched patients who received BMSs in vessels with similar reference vessel diameters. Clinical outcomes at 30 days, 6 months, and 1 year were compared between groups. Baseline clinical and procedural characteristics were similar. Target lesion revascularization and target vessel revascularization rates and the incidence of major adverse cardiac events were low and comparable between the 2 groups at all follow-up intervals. At 1 year, the primary outcome occurred in 8.5% of patients with DESs and 7.7% of patients with BMSs (p = 0.80). There were no episodes of subacute stent thrombosis or late thrombosis in either group. In conclusion, implantation of DESs in large coronary arteries confers no additional benefit compared with BMSs, and the 2 approaches are associated with equally favorable clinical outcomes at 1 year.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17317356     DOI: 10.1016/j.amjcard.2006.09.105

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Cobalt-chromium stents in long lesions of large vessels: clinical and angiographic results.

Authors:  Iñigo Lozano; Carlos Cuellas; Pablo Avanzas; Armando Pérez de Prado; Concepción Suárez; Juan Rondan; Daehyun Lee; Jesus M de la Hera; Felipe Fernández; César Morís
Journal:  Tex Heart Inst J       Date:  2011

2.  Short- and long-term benefits of drug-eluting stents compared to bare metal stents even in treatment for large coronary arteries.

Authors:  Taiji Yoshida; Kenji Sakata; Yutaka Nitta; Tomio Taguchi; Bunji Kaku; Shoji Katsuda; Masaya Shimojima; Tadatsugu Gamou; Takuya Nakahashi; Tetsuo Konno; Masa-Aki Kawashiri; Masakazu Yamagishi; Kenshi Hayashi
Journal:  Heart Vessels       Date:  2015-03-11       Impact factor: 2.037

3.  Comparison of bare-metal stents and drug-eluting stents in coronary ostial lesions (from the National Heart, Lung, and Blood Institute Dynamic Registry).

Authors:  Samip Vasaiwala; Helen Vlachos; Faith Selzer; Oscar Marroquin; Suresh Mulukutla; J Dawn Abbott; David O Williams
Journal:  Am J Cardiol       Date:  2012-07-03       Impact factor: 2.778

4.  Effectiveness of drug-eluting stents versus bare-metal stents in large coronary arteries in patients with acute myocardial infarction.

Authors:  Doo Sun Sim; Myung Ho Jeong; Youngkeun Ahn; Young Jo Kim; Shung Chull Chae; Taek Jong Hong; In Whan Seong; Jei Keon Chae; Chong Jin Kim; Myeong Chan Cho; Ki Bae Seung; Seung Jung Park
Journal:  J Korean Med Sci       Date:  2011-03-28       Impact factor: 2.153

5.  Nine-year clinical outcomes of drug-eluting stents vs. bare metal stents for large coronary vessel lesions.

Authors:  Dong Yin; Jia Li; Yue-Jin Yang; Yang Wang; Yan-Yan Zhao; Shi-Jie You; Shu-Bin Qiao; Bo Xu; Ke-Fei Dou
Journal:  J Geriatr Cardiol       Date:  2017-01       Impact factor: 3.327

6.  Impact of stent length and diameter on short term clinical outcomes of drug eluting stents in patients with stable coronary artery disease.

Authors:  Yasir Adnan; Lubna Noor; Muhammad Habeel Dar; Umair Ali; Muhammad Hafizullah
Journal:  Pak J Med Sci       Date:  2017 Jul-Aug       Impact factor: 1.088

7.  Disparities In The Use Of Drug-eluting Stents For Diabetic Patients With ST-elevation Acute Myocardial Infarction Assisted In the Public versus Private Network - VICTIM Register.

Authors:  Jussiely Cunha Oliveira; Laís Costa Souza Oliveira; Jeferson Cunha Oliveira; Ikaro Daniel de Carvalho Barreto; Marcos Antonio Almeida-Santos; Ticiane Clair Remacre Munareto Lima; Larissa Andreline Maia Arcelino; Isadora Soares Bispo Santos Silva; Antônio Carlos Sobral Sousa; José Augusto Soares Barreto-Filho
Journal:  Arq Bras Cardiol       Date:  2019-03-14       Impact factor: 2.000

  7 in total