Literature DB >> 17316478

Effect of plasma volume loss during graded exercise testing on blood lactate concentration.

James A Davis1, Ralph Rozenek, Derek M Decicco, Michael T Carizzi, Patrick H Pham.   

Abstract

Previous studies have shown that plasma volume (PV) loss can be a confounding variable in the interpretation of changes in blood constituents. We examined the effect of PV loss on three features of the blood lactate versus work-rate relationship, namely, slight blood lactate increase during the early stages of graded exercise testing (GXT); work rate at the onset of a systematic increase in blood lactate, i.e., lactate threshold (LT); and work rate at a blood lactate concentration of 4 mM, i.e., onset of blood lactate accumulation (OBLA). Fourteen subjects underwent cycle ergometer GXT. Blood samples were obtained at rest and at the end of each 3-min work-rate increment and analyzed for hematocrit and lactate concentration. For exercise levels up to and including LT, PV loss was relatively stable at approximately 2.8%. Beyond LT, PV loss accelerated. From the first work rate to LT, blood lactate concentration uncorrected for PV loss increased 0.24 +/- 0.07 mM (P < 0.05). After correction for PV loss, the increase was 0.21 +/- 0.08 mM (P < 0.05). These mean increases were not significantly different from each other. For the four exercise levels above LT common to most subjects, PV-corrected lactate values were significantly lower than uncorrected values. Correction of lactate values for PV loss did not alter LT for any subject, but it did result in a significant increase in OBLA. Thus, PV loss has the potential to be a confounding variable for the interpretation of blood lactate parameters that are determined at exercise levels above LT.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17316478     DOI: 10.2170/physiolsci.rp014406

Source DB:  PubMed          Journal:  J Physiol Sci        ISSN: 1880-6546            Impact factor:   2.781


  2 in total

1.  Salivary and plasma levels of matrix metalloproteinase-9 and myeloperoxidase at rest and after acute physical exercise in patients with coronary artery disease.

Authors:  Zeid Mahmood; Helena Enocsson; Maria Bäck; Rosanna W S Chung; Anna K Lundberg; Lena Jonasson
Journal:  PLoS One       Date:  2019-02-06       Impact factor: 3.240

2.  Fiber-based lactate recordings with fluorescence resonance energy transfer sensors by applying an magnetic resonance-informed correction of hemodynamic artifacts.

Authors:  Henriette Lambers; Lydia Wachsmuth; Dominik Thomas; Fawzi Boumezbeur; Vanessa Hoesker; Bruno Pradier; Cornelius Faber
Journal:  Neurophotonics       Date:  2022-05-09       Impact factor: 4.212

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.