Literature DB >> 17314683

Cardiac output measurement using a modified carbon dioxide Fick method: a validation study in ventilated lambs.

Willem P de Boode1, Jeroen C W Hopman, Otto Daniëls, Hans G van der Hoeven, K Djien Liem.   

Abstract

Cardiac output can be measured using a modified carbon dioxide Fick (mCO2F) method. A validation study was performed comparing mCO2F method-derived cardiac output (Q(mCO2F)) with invasively measured pulmonary blood flow. In seven randomly bred ventilated newborn lambs, cardiac output was manipulated by creating hemorrhagic hypotension. When steady state was reached, Q(mCO2F) was measured. Gas analysis was performed in simultaneously obtained arterial and venous blood samples (right atrium [RA], superior vena cava [SVC], and inferior vena cava [IVC]). Carbon dioxide exchange and pulmonary blood flow was measured continuously using a CO2SMO Plus monitor and a pulmonary ultrasonic flow probe (Q), respectively. Mean bias, defined as Q(mCO2F) - Q(ufp), was small (respectively, -0.082 L.min, -0.085 Lx min(-1) and -0.183 Lxmin(-1) for venous sampling from RA, SVC, and IVC). The limits of agreement were -0.328 to 0.164 Lxmin(-1) (RA), -0.335 to 0.165 Lxmin(-1) (SVC), and 0.415 to 0.049 Lxmin(-1) (IVC). In conclusion, measurement of cardiac output with the mCO2F method is reliable and easily applicable in ventilated newborn lambs. For clinical use, the site of venous blood sampling is of minor importance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17314683     DOI: 10.1203/pdr.0b013e318030d0c6

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  4 in total

1.  Noninvasive photoacoustic measurement of the composite indicator dilution curve for cardiac output estimation.

Authors:  DongYel Kang; Qiaojian Huang; Youzhi Li
Journal:  Biomed Opt Express       Date:  2015-01-15       Impact factor: 3.732

2.  Cardiac output measurement using a modified carbon dioxide Fick method: comparison analysis with pulmonary artery catheter method and pulse induced contour cardiac output method.

Authors:  Tong Li; Hongliu Cai; Hui Pan; Qibin Pu
Journal:  Int J Clin Exp Med       Date:  2015-03-15

Review 3.  Cardiac Output Monitoring in Preterm Infants.

Authors:  Matthew McGovern; Jan Miletin
Journal:  Front Pediatr       Date:  2018-04-03       Impact factor: 3.418

4.  Effect of supplemental dexmedetomidine in interventional embolism on cerebral oxygen metabolism in patients with intracranial aneurysms.

Authors:  Zhang Guo; Weiwei Wang; Dahua Xie; Ruisheng Lin
Journal:  J Int Med Res       Date:  2021-04       Impact factor: 1.671

  4 in total