Literature DB >> 17314647

Interobserver and intraobserver reliability in lower-limb deformity correction measurements.

David S Feldman1, Eric R Henderson, Harlan B Levine, Philip L Schrank, Kenneth J Koval, Raviraj J Patel, Daniel B Spencer, Debra A Sala, Kenneth A Egol.   

Abstract

Planning for surgical correction of lower-limb deformity requires assessment of the character and extent of the deformity. Deformity measurements are defined; however, the reliability of these measurements has not been evaluated. This study was conducted to assess the interobserver and intraobserver reliability of lower extremity deformity measurements in the frontal and sagittal planes. Anteroposterior and lateral lower extremity radiographs were evaluated using Paley technique. Statistical analysis included intraclass correlation coefficient (2,1), median absolute difference, range, and agreement within 3 and 5 degrees. Reliability was good to very good for all measurements except for the anterior distal tibial angle, which had moderate reliability. Intraobserver reliability was higher than interobserver reliability, and measurements in the frontal plane had better reliability than measurements in the sagittal plane. Overall, these measurements are a reliable method of assessing lower extremity deformity and should be used to guide treatment and monitor outcome.

Entities:  

Mesh:

Year:  2007        PMID: 17314647     DOI: 10.1097/01.bpb.0000242441.96434.6f

Source DB:  PubMed          Journal:  J Pediatr Orthop        ISSN: 0271-6798            Impact factor:   2.324


  10 in total

1.  Reliability of the assessment of lower limb torsion using computed tomography: analysis of five different techniques.

Authors:  Emmanouil Liodakis; Iosifina Doxastaki; Kongfai Chu; Christian Krettek; Ralph Gaulke; Musa Citak; Mohamed Kenawey
Journal:  Skeletal Radiol       Date:  2011-05-11       Impact factor: 2.199

2.  Reliability of lower-limb alignment measurements in patients with multiple epiphyseal dysplasia.

Authors:  Bekhzad Akhmedov; Ki Hyuk Sung; Chin Youb Chung; Kyoung Min Lee; Moon Seok Park
Journal:  Clin Orthop Relat Res       Date:  2012-09-05       Impact factor: 4.176

3.  What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2017-05-11       Impact factor: 3.075

4.  Recurrence of axial malalignment after surgical correction in congenital femoral deficiency and fibular hemimelia.

Authors:  Christof Radler; Giorgio Antonietti; Rudolf Ganger; Franz Grill
Journal:  Int Orthop       Date:  2011-05-03       Impact factor: 3.075

5.  Clinical and radiological outcomes of high tibial osteotomy with combined fixator-assisted nailing and subtubercle tibial osteotomy.

Authors:  Levent Bayam; Mehmet Erdem; Deniz Gülabi; Ahmet Can Erdem; Ahmet Çağrı Uyar; Alauddin Kochai
Journal:  Acta Orthop Traumatol Turc       Date:  2020-01       Impact factor: 1.511

6.  Radiographic classification of coronal plane femoral deformities in polyostotic fibrous dysplasia.

Authors:  Ernesto Ippolito; Pasquale Farsetti; Alison M Boyce; Alessandro Corsi; Fernando De Maio; Michael T Collins
Journal:  Clin Orthop Relat Res       Date:  2013-11-19       Impact factor: 4.176

7.  Automated Analysis of Alignment in Long-Leg Radiographs by Using a Fully Automated Support System Based on Artificial Intelligence.

Authors:  Justus Schock; Daniel Truhn; Daniel B Abrar; Dorit Merhof; Stefan Conrad; Manuel Post; Felix Mittelstrass; Christiane Kuhl; Sven Nebelung
Journal:  Radiol Artif Intell       Date:  2020-12-23

8.  Changing from analog to digital images: does it affect the accuracy of alignment measurements of the lower extremity?

Authors:  Martina Lohman; Kaj Tallroth; Jyrki A Kettunen; Ville Remes
Journal:  Acta Orthop       Date:  2011-06       Impact factor: 3.717

9.  Is there a correlation between the change in the interscrew angle of the eight-plate and the delta joint orientation angles?

Authors:  Salih Marangoz; Kadir Buyukdogan; Sevilay Karahan
Journal:  Acta Orthop Traumatol Turc       Date:  2016-12-29       Impact factor: 1.511

10.  The reliability of full-length lower limb radiographic alignment measurements in skeletally immature youth.

Authors:  G A Schmale; A F Bayomy; A O O'Brien; V Bompadre
Journal:  J Child Orthop       Date:  2019-02-01       Impact factor: 1.548

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.