Literature DB >> 17314460

The usefulness of sleep apnea syndrome screening using a portable pulse oximeter in the workplace.

Kuniyuki Niijima1, Kazuhiko Enta, Hiroko Hori, Shunsuke Sashihara, Tetsuya Mizoue, Yasuo Morimoto.   

Abstract

Sleep Apnea Syndrome (SAS) is a condition characterized by sleep-disordered breathing resulting in health impairment and sleep problems. From the viewpoints of the prevention of health impairment, accidents at work and traffic accidents, active implementation of screening for SAS in workplaces is necessary. Using a portable pulse oximeter, we conducted SAS screening for workers, who applied for the screening or who were instructed to participate by occupational physicians based on their symptoms at the time of medical check-up, in order to evaluate the effectiveness of a portable pulse oximeter as a screening device in the workplace. During the 2-yr study period from April 2002 to March 2004, 380 workers underwent overnight pulse oximetry at home; data on 367 of them were considered valid and included in the analysis. We deemed screening-positive as oxygen desaturation of the peripheral artery of 4% or greater if 10 or more events were observed per hour (ODI4> or =10); or oxygen desaturation of the peripheral artery of 3% or greater if 15 or more events were observed per hour (ODI3> or =15). Eighty-three subjects were identified as screening-positive and 54 of them underwent polysomnography. All of them were diagnosed as having SAS with an apnea hypopnea index (AHI)> or =5, of which continuous positive airway pressure (CPAP) therapy was indicated in 48 cases (88.9%) with AHI> or =20. On the other hand, 11 of the 284 screening-negative subjects with mild sleep disordered breathing underwent polysomnography and all of them were diagnosed as having SAS with AHI> or =5. However, CPAP therapy was indicated only for 5 with AHI> or =20 of the 11. Therefore, in total, 65 subjects were diagnosed with SAS in this study and for 53 of them CPAP therapy was indicated. The simplicity of the SAS screening by pulse oximetry makes it easy to use for screening of workers, and this method was highly effective in detecting individuals with severe SAS for whom CPAP therapy was indicated.

Entities:  

Mesh:

Year:  2007        PMID: 17314460     DOI: 10.1539/joh.49.1

Source DB:  PubMed          Journal:  J Occup Health        ISSN: 1341-9145            Impact factor:   2.708


  5 in total

1.  Sleep disordered breathing analysis in a general population using standard pulse oximeter signals.

Authors:  Deganit Barak-Shinar; Yariv Amos; Richard K Bogan
Journal:  Sleep Breath       Date:  2013-02-06       Impact factor: 2.816

2.  Influence of sleep-disordered breathing assessed by pulse oximetry on long-term clinical outcomes in patients who underwent percutaneous coronary intervention.

Authors:  Shoichiro Yatsu; Ryo Naito; Takatoshi Kasai; Hiroki Matsumoto; Jun Shitara; Megumi Shimizu; Azusa Murata; Takao Kato; Shoko Suda; Masaru Hiki; Eiryu Sai; Katsumi Miyauchi; Hiroyuki Daida
Journal:  Clin Res Cardiol       Date:  2018-03-31       Impact factor: 5.460

3.  Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography?

Authors:  Arthur Dawson; Richard T Loving; Robert M Gordon; Susan L Abel; Derek Loewy; Daniel F Kripke; Lawrence E Kline
Journal:  BMJ Open       Date:  2015-06-30       Impact factor: 2.692

4.  Investigation of Obstructive Sleep Apnea Using Portable Monitors and Health Check Data in Japanese Drivers.

Authors:  Masako Ueyama; Hiroyuki Kokuto; Hitoshi Sugihara; Shinichi Oikawa; Fumio Suzuki; Hajime Goto; Shoji Kudoh
Journal:  J Atheroscler Thromb       Date:  2018-03-05       Impact factor: 4.928

5.  Evaluation of candidate measures for home-based screening of sleep disordered breathing in Taiwanese bus drivers.

Authors:  Hua Ting; Ren-Jing Huang; Ching-Hsiang Lai; Shen-Wen Chang; Ai-Hui Chung; Teng-Yao Kuo; Ching-Haur Chang; Tung-Sheng Shih; Shin-Da Lee
Journal:  Sensors (Basel)       Date:  2014-05-05       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.