Literature DB >> 17314360

Comparative performance of the Roche COBAS Amplicor assay and an in-house real-time PCR assay for diagnosis of Chlamydia trachomatis infection.

Hamid Jalal1, Abdulrahman Al-Suwaine2, Hannah Stephen1, Christopher Carne3, Christopher Sonnex3.   

Abstract

This study investigated the comparative performance of the Amplicor assay and an in-house semi-automated, multiplex real-time PCR for the diagnosis of genital chlamydial infection. Four different assays, the COBAS Amplicor CT test (Amplicor PCR), in-house real-time PCR (IHRT-PCR), in-house nested cryptic plasmid PCR and in-house nested major outer membrane protein PCR, were performed on genital swabs from 1000 consecutive patients attending a genitourinary medicine clinic. The samples were designated true positive if Chlamydia trachomatis DNA was detected by at least two of the four above-mentioned assays while a sample was defined as true negative if C. trachomatis DNA was detected in only one or none of the assays. By this criterion, there were 129 true positive and 871 true negative samples for C. trachomatis DNA in this cohort. Amplicor PCR designated 144 samples positive: 128 (89%) of 144 samples were true positive and 16 (11%) were false positive. IHRT-PCR detected 126 of 129 true positive samples and did not generate any false positive results. The sensitivity of IHRT-PCR was comparable with, and specificity was higher than, Amplicor PCR for the diagnosis of genital chlamydial infection.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17314360     DOI: 10.1099/jmm.0.46762-0

Source DB:  PubMed          Journal:  J Med Microbiol        ISSN: 0022-2615            Impact factor:   2.472


  3 in total

1.  Decline in the prevalence of HIV and sexually transmitted infections among female sex workers in Benin over 15 years of targeted interventions.

Authors:  Luc Béhanzin; Souleymane Diabaté; Isaac Minani; Marie-Claude Boily; Annie-Claude Labbé; Clément Ahoussinou; Séverin Anagonou; Djimon M Zannou; Catherine M Lowndes; Michel Alary
Journal:  J Acquir Immune Defic Syndr       Date:  2013-05-01       Impact factor: 3.731

2.  Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in an STI population: performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor with urine specimens and urethral/cervicovaginal samples.

Authors:  T A Schuurs; S P Verweij; J F L Weel; S Ouburg; S A Morré
Journal:  BMJ Open       Date:  2013-12-30       Impact factor: 2.692

3.  Rapid screening for Chlamydia trachomatis infection by detecting α-mannosidase activity in urogenital tract specimens.

Authors:  Ze-yu Wang; Guang-yu Fu; Shan-mei Wang; Dong-chun Qin; Zhong-quan Wang; Jing Cui
Journal:  BMC Infect Dis       Date:  2013-01-24       Impact factor: 3.090

  3 in total