Literature DB >> 17313952

Heterogeneous mechanomyographic absolute activation of paraspinal muscles assessed by a two-dimensional array during short and sustained contractions.

Pascal Madeleine1, Kylie Tuker, Lars Arendt-Nielsen, Dario Farina.   

Abstract

Spatial dependency of paraspinal muscle activity was assessed using a new two-dimensional MMG recording system. MMG signals were detected over the left and right paraspinal muscles of 10 volunteers using a grid of 12 accelerometers. During two separate trials subjects maintained a 20 degrees flexed position and held loads that ranged from 0 to 15 kg (in 2.5 kg increments) for 20s; and 7.5 kg for 6 min. Maps of absolute and normalised (with respect to initial values) average rectified value, mean power frequency, variance and skewness of the power spectral density were obtained from the two-dimensional MMG recordings. For both the short duration and sustained contractions, the MMG absolute average rectified value, mean power frequency, variance and skewness depended on accelerometer location (P<0.05), while, with the exception of the skewness (P<0.05), normalised values did not. These results demonstrate both inhomogeneous MMG absolute activity and homogeneous MMG normalised activity in paraspinal muscles for short duration and sustained contractions. Moreover, the effect of accelerometer location on spectral variables confirmed the limited validity of general relationships between MMG spectral changes and motor unit recruitment strategies. This study underlines the importance of using multiple recording sites when assessing back muscle activity.

Mesh:

Year:  2007        PMID: 17313952     DOI: 10.1016/j.jbiomech.2006.12.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Time to task failure in shoulder elevation is associated to increase in amplitude and to spatial heterogeneity of upper trapezius mechanomyographic signals.

Authors:  Pascal Madeleine; Dario Farina
Journal:  Eur J Appl Physiol       Date:  2007-10-18       Impact factor: 3.078

2.  Longitudinal and transverse propagation of surface mechanomyographic waves generated by single motor unit activity.

Authors:  Corrado Cescon; Pascal Madeleine; Dario Farina
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

Review 3.  Peripheral fatigue: new mechanistic insights from recent technologies.

Authors:  Emiliano Cè; Stefano Longo; Eloisa Limonta; Giuseppe Coratella; Susanna Rampichini; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2019-11-19       Impact factor: 3.078

4.  Effects of age and stimulus on submental mechanomyography signals during swallowing.

Authors:  Joon Lee; Tom Chau; Catriona M Steele
Journal:  Dysphagia       Date:  2009-01-14       Impact factor: 3.438

5.  The effect of accelerometer location on the classification of single-site forearm mechanomyograms.

Authors:  Natasha Alves; Ervin Sejdić; Bhupinder Sahota; Tom Chau
Journal:  Biomed Eng Online       Date:  2010-06-10       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.