Literature DB >> 17313335

Fetal ECG extraction during labor using an adaptive maternal beat subtraction technique.

Mihaela Ungureanu1, Johannes W M Bergmans, Swan Guid Oei, Rodica Strungaru.   

Abstract

Fetal ECG (FECG) monitoring using abdominal maternal signals is a non-invasive technique that allows early detection of changes in fetal wellbeing. Several other signal components have stronger energy than the FECG, the most important being maternal ECG (MECG) and, especially during labor, uterine EMG. This study proposes a new method to subtract MECG after detecting and removing abdominal signal segments with high-amplitude variations due to uterine contractions. The method removes MECG from abdominal signals using an approximation of the current MECG segment based on a linear combination of previous MECG segments aligned on the R-peak. The coefficients of the linear model are computed so that the squared error of the approximation over the whole current segment is minimized. Abdominal signal segments strongly affected by uterine contractions are detected by applying median filtering. The methods proposed are tested on real abdominal data recorded during labor, with FECG recorded using scalp electrodes synchronously recorded for comparison.

Entities:  

Mesh:

Year:  2007        PMID: 17313335     DOI: 10.1515/BMT.2007.011

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  8 in total

Review 1.  Noninvasive fetal electrocardiography: an overview of the signal electrophysiological meaning, recording procedures, and processing techniques.

Authors:  Angela Agostinelli; Marla Grillo; Alessandra Biagini; Corrado Giuliani; Luca Burattini; Sandro Fioretti; Francesco Di Nardo; Stefano R Giannubilo; Andrea Ciavattini; Laura Burattini
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-02-02       Impact factor: 1.468

2.  Influence of electrode placement on signal quality for ambulatory pregnancy monitoring.

Authors:  M J Rooijakkers; S Song; C Rabotti; S G Oei; J W M Bergmans; E Cantatore; M Mischi
Journal:  Comput Math Methods Med       Date:  2014-02-03       Impact factor: 2.238

3.  Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

Authors:  Janusz Jezewski; Janusz Wrobel; Adam Matonia; Krzysztof Horoba; Radek Martinek; Tomasz Kupka; Michal Jezewski
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

4.  An Efficient and Robust Deep Learning Method with 1-D Octave Convolution to Extract Fetal Electrocardiogram.

Authors:  Khuong Vo; Tai Le; Amir M Rahmani; Nikil Dutt; Hung Cao
Journal:  Sensors (Basel)       Date:  2020-07-04       Impact factor: 3.576

5.  A Null Space-Based Blind Source Separation for Fetal Electrocardiogram Signals.

Authors:  Luay Taha; Esam Abdel-Raheem
Journal:  Sensors (Basel)       Date:  2020-06-22       Impact factor: 3.576

6.  Fetal Electrocardiogram Extraction from the Mother's Abdominal Signal Using the Ensemble Kalman Filter.

Authors:  Sadaf Sarafan; Tai Le; Michael P H Lau; Afshan Hameed; Tadesse Ghirmai; Hung Cao
Journal:  Sensors (Basel)       Date:  2022-04-05       Impact factor: 3.576

7.  Investigation of Methods to Extract Fetal Electrocardiogram from the Mother's Abdominal Signal in Practical Scenarios.

Authors:  Sadaf Sarafan; Tai Le; Amir Mohammad Naderi; Quoc-Dinh Nguyen; Brandon Tiang-Yu Kuo; Tadesse Ghirmai; Huy-Dung Han; Michael P H Lau; Hung Cao
Journal:  Technologies (Basel)       Date:  2020-06-05

8.  Invariant heart beat span versus variant heart beat intervals and its application to fetal ECG extraction.

Authors:  Huawen Yan; Hongxing Liu; Xiaolin Huang; Ying Zhao; Junfeng Si; Tiebing Liu
Journal:  Biomed Eng Online       Date:  2014-12-12       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.