Literature DB >> 17311407

Electrochemical immunosensor using p-aminophenol redox cycling by hydrazine combined with a low background current.

Jagotamoy Das1, Kyungmin Jo, Jae Wook Lee, Haesik Yang.   

Abstract

Signal amplification and noise reduction are crucial for obtaining low detection limits in biosensors. Here, we present an electrochemical immunosensor in which the signal amplification is achieved using p-aminophenol (AP) redox cycling by hydrazine, and the noise level is reduced by implementing a low background current. The redox cycling is obtained in a simple one-electrode, one-enzyme format. In a sandwich-type heterogeneous immunosensor for mouse IgG, an alkaline phosphatase label converts p-aminophenyl phosphate into AP for 10 min. This generated AP is electrooxidized at an indium tin oxide (ITO) electrode modified with a partially ferrocenyl-tethered dendrimer (Fc-D). The oxidized product, p-quinone imine (QI), is reduced back to AP by hydrazine, and then AP is electrooxidized again to QI, resulting in redox cycling. Moreover, hydrazine protects AP from oxidation by air, enabling long incubation times. The small amount of ferrocene in a 0.5% Fc-D-modified ITO electrode, where 0.5% represents the ratio of ferrocene groups to dendrimer amines, results in a low background current, and this electrode exhibits high electron-mediating activity for AP oxidation. Moreover, there is insignificant hydrazine electrooxidation on this electrode, which also results in a low background current. The detection limit of the immunosensor using a 0.5% Fc-D-modified electrode is 2 orders of magnitude lower than that of a 20% Fc-D-modified electrode (10 pg/mL vs 1 ng/mL). Furthermore, the presence of hydrazine reduces the detection limit by an additional 2 orders of magnitude (100 fg/mL vs 10 pg/mL). These results indicate that the occurrence of redox cycling combined with a low background current yields an electrochemical immunosensor with a very low detection limit (100 fg/mL). Mouse IgG could be detected at concentrations ranging from 100 fg/mL to 100 microg/mL (i.e., 9 orders of magnitude) in a single assay.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17311407     DOI: 10.1021/ac062291l

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2008-05-21       Impact factor: 6.986

2.  Silver Nanocubes as Electrochemical Labels for Bioassays.

Authors:  Yi Peng; Charlie Rabin; Charuksha T Walgama; Nicole E Pollok; Leilani Smith; Ian Richards; Richard M Crooks
Journal:  ACS Sens       Date:  2021-01-13       Impact factor: 7.711

3.  An ultrasensitive universal detector based on neutralizer displacement.

Authors:  Jagotamoy Das; Kristin B Cederquist; Alexandre A Zaragoza; Paul E Lee; Edward H Sargent; Shana O Kelley
Journal:  Nat Chem       Date:  2012-06-03       Impact factor: 24.427

4.  Sensitive and direct electrochemical detection of double-stranded DNA utilizing alkaline phosphatase-labelled zinc finger proteins.

Authors:  Soodong Noh; Dat Thinh Ha; Haesik Yang; Moon-Soo Kim
Journal:  Analyst       Date:  2015-05-13       Impact factor: 4.616

5.  Redox cycling amplified electrochemical detection of DNA hybridization: application to pathogen E. coli bacterial RNA.

Authors:  Anne Walter; Jie Wu; Gerd-Uwe Flechsig; David A Haake; Joseph Wang
Journal:  Anal Chim Acta       Date:  2011-01-18       Impact factor: 6.558

6.  Redox-based inactivation of cysteine cathepsins by compounds containing the 4-aminophenol moiety.

Authors:  Bojana Mirković; Izidor Sosič; Stanislav Gobec; Janko Kos
Journal:  PLoS One       Date:  2011-11-04       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.