AIM: To assess ex vivo the cytotoxic effects of five new root canal sealers (RC Sealer, Epiphany, EndoREZ, GuttaFlow and Acroseal) and three existing products (AH Plus, RoekoSeal and Apexit) using primary human gingival fibroblasts (HGF) and a mouse fibroblast cell line, L929. METHODOLOGY: Eight samples of each sealer were fabricated in sterile cylindrical Teflon blocks, 4.4 mm diameter and 2 mm height and then divided into two groups, fresh and aged specimens. Extraction of fresh specimens was carried out after setting whilst aged specimens were placed in Petri dishes and kept in a humid chamber at 37 degrees C for 7 days before extraction in cell culture medium using the ratio 1.25 cm(2) mL(-1). Undiluted eluates were used for the dimethylthiazol diphenyltetrazolium bromide (MTT) assay with HGF and L-929. Morphology of HGF cells was also examined by an inverted microscope using undiluted eluates of the sealers. The results were analysed using a two-tailed t-test (alpha = 0.05) between groups. RESULTS: Resin-based (Epiphany and EndoREZ) and calcium hydroxide-based (Apexit and Acroseal) sealers were significantly more cytotoxic than other sealers (P<0.05). However, L929 cells were more sensitive to Apexit and EndoREZ than HGF cells. RC Sealer showed mild cytotoxicity to HGF at both setting times. AH Plus did not exert any cytotoxic effect to HGF and aged specimens appeared to induce cellular proliferation. RoekoSeal and GuttaFlow also demonstrated mild cytotoxicity. GuttaFlow was slightly more cytotoxic to both cultures, especially when tested fresh. CONCLUSIONS: Toxicity varied but RC Sealer and GuttaFlow were the least toxic new sealers.
AIM: To assess ex vivo the cytotoxic effects of five new root canal sealers (RC Sealer, Epiphany, EndoREZ, GuttaFlow and Acroseal) and three existing products (AH Plus, RoekoSeal and Apexit) using primary human gingival fibroblasts (HGF) and a mouse fibroblast cell line, L929. METHODOLOGY: Eight samples of each sealer were fabricated in sterile cylindrical Teflon blocks, 4.4 mm diameter and 2 mm height and then divided into two groups, fresh and aged specimens. Extraction of fresh specimens was carried out after setting whilst aged specimens were placed in Petri dishes and kept in a humid chamber at 37 degrees C for 7 days before extraction in cell culture medium using the ratio 1.25 cm(2) mL(-1). Undiluted eluates were used for the dimethylthiazol diphenyltetrazolium bromide (MTT) assay with HGF and L-929. Morphology of HGF cells was also examined by an inverted microscope using undiluted eluates of the sealers. The results were analysed using a two-tailed t-test (alpha = 0.05) between groups. RESULTS:Resin-based (Epiphany and EndoREZ) and calcium hydroxide-based (Apexit and Acroseal) sealers were significantly more cytotoxic than other sealers (P<0.05). However, L929 cells were more sensitive to Apexit and EndoREZ than HGF cells. RC Sealer showed mild cytotoxicity to HGF at both setting times. AH Plus did not exert any cytotoxic effect to HGF and aged specimens appeared to induce cellular proliferation. RoekoSeal and GuttaFlow also demonstrated mild cytotoxicity. GuttaFlow was slightly more cytotoxic to both cultures, especially when tested fresh. CONCLUSIONS: Toxicity varied but RC Sealer and GuttaFlow were the least toxic new sealers.
Authors: Gleyce O Silva; Bruno N Cavalcanti; Tatiana R Oliveira; Claudia V Bin; Samira E A Camargo; Carlos H R Camargo Journal: Clin Oral Investig Date: 2015-08-29 Impact factor: 3.573
Authors: Pranab Misra; Rhythm Bains; Kapil Loomba; Abhinav Singh; V P Sharma; R C Murthy; Rakesh Kumar Journal: J Oral Biol Craniofac Res Date: 2016-04-16
Authors: S Ghanaati; I Willershausen; M Barbeck; R E Unger; M Joergens; R A Sader; C J Kirkpatrick; B Willershausen Journal: Eur J Med Res Date: 2010-11-25 Impact factor: 2.175