Literature DB >> 17308603

Forward and reverse product decompositions of depolarizing Mueller matrices.

Razvigor Ossikovski1, Antonello De Martino, Steve Guyot.   

Abstract

Because of the noncommutativity of the matrix product, the three factors into which a depolarizing Mueller matrix is decomposed, i.e., the diattenuator, the retarder, and the depolarizer, form six possible products grouped into two families, as already pointed out [J. Opt. Soc. Am. A13, 1106 (1996); Opt. Lett.29, 2234 (2004)]. We show that, apart from the generalized polar decomposition generating the first family of products, there exists a dual decomposition belonging to the second family. The mathematical procedure for this dual decomposition is given, and the symmetry existing between the two decompositions is pointed out. The choice of the most appropriate decomposition for a given practical optical arrangement is likewise discussed and illustrated by simple examples.

Entities:  

Year:  2007        PMID: 17308603     DOI: 10.1364/ol.32.000689

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  5 in total

1.  Imaging linear and circular polarization features in leaves with complete Mueller matrix polarimetry.

Authors:  C H Lucas Patty; David A Luo; Frans Snik; Freek Ariese; Wybren Jan Buma; Inge Loes Ten Kate; Rob J M van Spanning; William B Sparks; Thomas A Germer; Győző Garab; Michael W Kudenov
Journal:  Biochim Biophys Acta Gen Subj       Date:  2018-03-09       Impact factor: 3.770

2.  Fast spectrally encoded Mueller optical scanning microscopy.

Authors:  Sylvain Rivet; Matthieu Dubreuil; Adrian Bradu; Yann Le Grand
Journal:  Sci Rep       Date:  2019-03-08       Impact factor: 4.379

3.  Phasor approach of Mueller matrix optical scanning microscopy for biological tissue imaging.

Authors:  Aymeric Le Gratiet; Luca Lanzano; Artemi Bendandi; Riccardo Marongiu; Paolo Bianchini; Colin Sheppard; Alberto Diaspro
Journal:  Biophys J       Date:  2021-07-03       Impact factor: 3.699

4.  Polarimetric observables for the enhanced visualization of plant diseases.

Authors:  Carla Rodríguez; Enrique Garcia-Caurel; Teresa Garnatje; Mireia Serra I Ribas; Jordi Luque; Juan Campos; Angel Lizana
Journal:  Sci Rep       Date:  2022-08-30       Impact factor: 4.996

5.  Mueller Matrix Measurement of Electrospun Fiber Scaffolds for Tissue Engineering.

Authors:  Dierk Fricke; Alexander Becker; Lennart Jütte; Michael Bode; Dominik de Cassan; Merve Wollweber; Birgit Glasmacher; Bernhard Roth
Journal:  Polymers (Basel)       Date:  2019-12-11       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.