Literature DB >> 17307503

New transverse plate fixation system for complicated sternal wound infection after median sternotomy.

Andre Plass1, Jürg Grünenfelder, Oliver Reuthebuch, Robert Vachenauer, Jean-Marc Gauer, Gregor Zünd, Michele Genoni.   

Abstract

Wire fixation after median sternotomy is a safe procedure, but it is still associated with potential wound infection including bony dehiscence. In case of infection and dehiscence the sternum is re-fixated with steel wires. If this is insufficient, then flap reconstruction would be another option. We describe an alternative way for complicated sternal closure by using a rigid sternal fixation system that is feasible for cardiac surgeons. Three patients suffering from sternal instability and infection were operated on with the new titanium plates. The procedures were uneventful and short-term follow-up showed stable sternal conditions. In this report the technical concept has been described in detail in 1 patient. This new sternal fixation technique is safe and easy to handle and broadens the spectrum for closure of complicated sternal wound infections or dehiscence.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17307503     DOI: 10.1016/j.athoracsur.2006.03.080

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  Overview and management of sternal wound infection.

Authors:  Kimberly Singh; Erica Anderson; J Garrett Harper
Journal:  Semin Plast Surg       Date:  2011-02       Impact factor: 2.314

2.  Sternal Precautions: Is It Time for Change? Precautions versus Restrictions - A Review of Literature and Recommendations for Revision.

Authors:  Lawrence P Cahalin; Tanya Kinney Lapier; Donald K Shaw
Journal:  Cardiopulm Phys Ther J       Date:  2011-03

Review 3.  Review of Biomechanical Studies and Finite Element Modeling of Sternal Closure Using Bio-Active Adhesives.

Authors:  Amatulraheem Al-Abassi; Marcello Papini; Mark Towler
Journal:  Bioengineering (Basel)       Date:  2022-05-03

4.  Unexpected results after sternal reconstruction with plates, cables and cannulated screws.

Authors:  Stephanie Grabert; Magdalena Erlebach; Albrecht Will; Rüdiger Lange; Bernhard Voss
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-01-26

5.  Mitral valve replacement via minimally invasive totally thoracoscopic surgery versus traditional median sternotomy: a propensity score matched comparative study.

Authors:  Jian Liu; Bo Chen; Yu-Yuan Zhang; Liang-Zheng Fang; Bin Xie; Huan-Lei Huang; Jing Liu; Cong Lu; Wen-Da Gu; Zhao Chen; Jie-Xu Ma; Hai-Yun Yuan; Ji-Mei Chen; Jian Zhuang; Hui-Ming Guo
Journal:  Ann Transl Med       Date:  2019-07

6.  Titanium plate fixation for sternal dehiscence in major cardiac surgery.

Authors:  Wan Kee Kim; Joon Bum Kim; Gwan Sic Kim; Sung-Ho Jung; Suk Jung Choo; Cheol Hyun Chung; Jae Won Lee
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2013-08-06

7.  Treatment of traumatic sternal fractures with titanium plate internal fixation: a retrospective study.

Authors:  Yonghong Zhao; Yi Yang; Zongli Gao; Weiming Wu; Weiwei He; Tiancheng Zhao
Journal:  J Cardiothorac Surg       Date:  2017-04-04       Impact factor: 1.637