Literature DB >> 17304069

Detection of orthopaedic implants by airport metal detectors.

William T Obremskey1, Tom Austin, Colin Crosby, Robin Driver, Will Kurtz, Franklin Shuler, Philip Kregor.   

Abstract

OBJECTIVES: To report the effect of patient's body mass index (BMI), implant type, size, location, number, and material on detection by certified Transportation Security Administration (TSA) and Federal Aviation Administration (FAA) airport metal detectors set to today's standard sensitivity.
DESIGN: Retrospective clinical study.
SETTING: Level 1 university trauma center. PATIENTS: Ninety-six regularly scheduled trauma clinic patients with a wide variety of orthopaedic implants were enrolled in the study from August 2004 through December 2004. INTERVENTION: Patients walked through an airport arch metal detector and were also wanded with a handheld metal detector. MAIN OUTCOME MEASUREMENTS: Detection of implants by arch detector or wand was recorded. We also gathered information regarding BMI, location of implants, type, metal composition, and size.
RESULTS: All unilateral prostheses (8/8) and bilateral prostheses (1/1) were detected. Subjects with 4 or fewer screws and no other implants were never detected by the arch metal detector (0/7). For the remaining 78 subjects, the 2 best predictors of detection by the arch were having plates of length >10 holes and having titanium nails (P < 0.001 for each predictor, Wald's test for effects in a logistic model).
CONCLUSIONS: Prostheses, plates of length >10 holes, and titanium nails were the best predictors of detection by the arch. These 3 factors accounted for 42 of the 43 detections by the arch. Body mass index was not shown to affect detectability of orthopaedic implants.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17304069     DOI: 10.1097/BOT.0b013e31803071da

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  3 in total

1.  Prosthetic metal implants and airport metal detectors.

Authors:  A Ismail; A Dancey; O G Titley
Journal:  Ann R Coll Surg Engl       Date:  2013-04       Impact factor: 1.891

2.  Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis.

Authors:  Peter D Fabricant; Alex Robles; John S Blanco
Journal:  J Child Orthop       Date:  2013-09-08       Impact factor: 1.548

3.  The Need for an Implant Identification Card at Airport Security Check.

Authors:  Erden Ali; Dennis Kosuge; Andrew MacDowell
Journal:  Clin Orthop Surg       Date:  2017-05-08
  3 in total