Dosimetric parameters for small field sizes using Fricke xylenol gel, thermoluminescent and film dosimeters, and an ionization chamber.

Carmen S Guzmán Calcina1, Lucas N de Oliveira, Carlos E de Almeida, Adelaide de Almeida.   

Abstract

Dosimetric measurements in small therapeutic x-ray beam field sizes, such as those used in radiosurgery, that have dimensions comparable to or smaller than the build-up depth, require special care to avoid incorrect interpretation of measurements in regions of high gradients and electronic disequilibrium. These regions occur at the edges of any collimated field, and can extend to the centre of small fields. An inappropriate dosimeter can result in an underestimation, which would lead to an overdose to the patient. We have performed a study of square and circular small field sizes of 6 MV photons using a thermoluminescent dosimeter (TLD), Fricke xylenol gel (FXG) and film dosimeters. PMMA phantoms were employed to measure lateral beam profiles (1 x 1, 3 x 3 and 5 x 5 cm2 for square fields and 1, 2 and 4 cm diameter circular fields), the percentage depth dose, the tissue maximum ratio and the output factor. An ionization chamber (IC) was used for calibration and comparison. Our results demonstrate that high resolution FXG, TLD and film dosimeters agree with each other, and that an ionization chamber, with low lateral resolution, underestimates the absorbed dose. Our results show that, when planning small field radiotherapy, dosimeters with adequate lateral spatial resolution and tissue equivalence are required to provide an accurate basic beam data set to correctly calculate the absorbed dose in regions of electronic disequilibrium.

Entities:  

Mesh:

Year:  2007        PMID: 17301463     DOI: 10.1088/0031-9155/52/5/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Radiological tissue equivalence of deformable silicone-based chemical radiation dosimeters (FlexyDos3D).

Authors:  Yi Du; Ruoxi Wang; Meijiao Wang; Haizhen Yue; Yibao Zhang; Hao Wu; Weihu Wang
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

2.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

3.  Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.

Authors:  Henry Finlay Godson; M Ravikumar; S Sathiyan; K M Ganesh; Y Retna Ponmalar; C Varatharaj
Journal:  J Med Phys       Date:  2016 Jan-Mar

4.  Evaluation of NanoDot Optically Stimulated Luminescence Dosimeter for Cone-shaped Small-field Dosimetry of Cyberknife Stereotactic Radiosurgery Unit: A Monte Carlo Simulation and Dosimetric Verification Study.

Authors:  Fadil Akyol; Neslihan Sarigul; Mete Yeginer; Yagiz Yedekci; Haluk Utku
Journal:  J Med Phys       Date:  2019 Jan-Mar

5.  Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

Authors:  Lucas Sacchini Del Lama; Evamberto Garcia de Góes; Paulo César Dias Petchevist; Edson Lara Moretto; José Carlos Borges; Dimas Tadeu Covas; Adelaide de Almeida
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

6.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.