Literature DB >> 17300308

The effect of alcohol swabs and filter straws on reducing contamination of glass ampoules used for neuroaxial injections.

C J Hemingway1, S Malhotra, M Almeida, B Azadian, S M Yentis.   

Abstract

We have investigated the incidence of contamination of the contents of glass ampoules used for neuraxial injections, and whether this was reduced by wiping the outsides of the ampoules with isopropyl alcohol or using a filter straw. One hundred fentanyl and diamorphine ampoules used for routine regional anaesthesia were either wiped or not wiped with alcohol before their contents were aspirated, and the residual contents were swabbed and incubated. None of the swabs from the wiped ampoules grew organisms compared with nine (18%) from non-wiped ampoules (p = 0.004). In a second, laboratory study, 100 glass ampoules of saline were coated with Staphylococcus aureus and divided into four groups: wiped/not wiped with alcohol and with/without a filter straw. The contents of the ampoules were aspirated; the remnants and the aspirate were swabbed and incubated as before. Most contamination occurred in the unwiped groups and although numbers were small, filtering appeared to reduce contamination further. As filter straws also reduce the risk of injecting glass particles (even if not contaminated), our results suggest that wiping glass ampoules with isopropyl alcohol and using a filter straw should be part of routine practice when performing regional anaesthesia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17300308     DOI: 10.1111/j.1365-2044.2007.04977.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Bacterial Contamination of Anaesthetic and Vasopressor Drugs in the Operating Theatres: Ameliyathanelerde Anestetik ve Vazopressör İlaçların Bakteriyel Kontaminasyonu.

Authors:  Rongrong Rueangchira-Urai; Panthila Rujirojindakul; Alan Frederick Geater; Edward McNeil
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-02-01

2.  The effect of different methods of intravenous injection on glass particle contamination from ampules.

Authors:  Ga Eul Joo; Kyeong-Yae Sohng; Michael Yong Park
Journal:  Springerplus       Date:  2016-01-06

3.  Use of Oral Vitamin-D Glass ampoule and tablet: Experience of patients and physicians.

Authors:  Syed Umair Maroof; Faizan Shaukat; Junaid Aslam; Masood Jawaid
Journal:  Pak J Med Sci       Date:  2017 Mar-Apr       Impact factor: 1.088

4.  [SBA 2020: Regional anesthesia safety recommendations update].

Authors:  Liana Maria Tôrres de Araújo Azi; Neuber Martins Fonseca; Livia Gurgel Linard
Journal:  Braz J Anesthesiol       Date:  2020-05-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.