Development and clinical evaluation of a computerized limb volume measurement system (CLEMS).

J H Bednarczyk1, C Hershler, D G Cooper.   

Abstract

Limb edema is a common problem in both rehabilitation and acute care settings. In the past, attempts to determine an optimal management strategy for limb edema have been limited by the lack of accurate, noninvasive, rapid, clinical tools for quantifying limb volumes. The water displacement method is slow and difficult to use in the clinical setting. Furthermore, water displacement requires that the limb be in a dependent position. The tape measure method is unreliable because it is difficult to position the tape measure on a swollen limb. The development and evaluation of a new tool called the computerized limb volume measurement system (CLEMS) is described. The shape and volume of a limb or limb segment can be rapidly measured by CLEMS, independent of limb position. The limb volumes generated by CLEMS were compared to volumes determined by water displacement and by a tape measure. Volumes of eighteen legs (plaster, nonedematous and edematous) were measured using CLEMS, water displacement, and the tape measure. In all cases, the CLEMS and water displacement methods showed close agreement. CLEMS was found to be a reliable and valid new method of determining limb volume; whereas, the tape measure method was found to be invalid. This new tool allows clinicians to measure the efficacy of different treatment strategies in the management of limb edema.

Entities:  

Mesh:

Year:  1992        PMID: 1729976

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  5 in total

1.  Comparison between estimates of hand volume and hand strengths with sex and age with and without anthropometric data in healthy working people.

Authors:  N Chau; D Pétry; E Bourgkard; P Huguenin; E Remy; J M André
Journal:  Eur J Epidemiol       Date:  1997-04       Impact factor: 8.082

2.  The effects of loaded versus unloaded activities on foot volumetrics in older healthy adults.

Authors:  J Wesley McWhorter
Journal:  N Am J Sports Phys Ther       Date:  2008-02

3.  Asymmetry correction equations for hand volume, grip and pinch strengths in healthy working people.

Authors:  N Chau; E Remy; D Pétry; P Huguenin; E Bourgkard; J M André
Journal:  Eur J Epidemiol       Date:  1998-01       Impact factor: 8.082

4.  High day-to-day reliability in lower leg volume measured by water displacement.

Authors:  Jeffrey D Pasley; Patrick J O'Connor
Journal:  Eur J Appl Physiol       Date:  2008-07       Impact factor: 3.078

5.  Complex regional pain syndrome 1--the Swiss cohort study.

Authors:  Florian Brunner; Lucas M Bachmann; Ulrich Weber; Alfons G H Kessels; Roberto S G M Perez; Johan Marinus; Rudolf Kissling
Journal:  BMC Musculoskelet Disord       Date:  2008-06-23       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.