Reliability of knee flexor peak torque measurements from a standardized test protocol on a Kin/Com dynamometer.

C J Snow1, K Blacklin.   

Abstract

The test-retest reliability of a specific test protocol for the measurement of peak torque of the knee flexors using a Kin/Com dynamometer was evaluated. The maximum voluntary torque generated by the left knee flexors during constant velocity resisted-muscle shortening (RMS) and muscle lengthening (RML) was measured in a sitting position in 11 healthy women with no history of knee pathology. Each subject performed two tests at each of two velocities (30 degrees/sec and 180 degrees/sec) in a single session. All subjects repeated these four tests one week later. A test consisted of four complete RMS/RML cycles through a range of 65 degrees. The peak torque generated from each test was used to measure test-retest reliability. All data were gravity compensated. Intraclass correlation coefficients (ICCs) were calculated from ANOVA tests for RML and RMS at both velocities. The within sessions ICCs ranged from .94 to .98 for 30 degrees/sec and from .92 to .97 at 180 degrees/sec. The ICCs between sessions were generally lower and ranged from .79 to .90 for 30 degrees/sec, and from .75 to .88 for 180 degrees/sec. It is concluded that using these test protocols, peak torques for both RMS and RML can be measured with a high degree of reliability at two commonly used velocities.

Entities:  

Mesh:

Year:  1992        PMID: 1729967

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  4 in total

1.  A comparison of muscle training methods in patients with knee osteoarthritis.

Authors:  Sibel Eyigor; S Hepguler; K Capaci
Journal:  Clin Rheumatol       Date:  2004-02-05       Impact factor: 2.980

2.  The Reliability Of Three Isokinetic Knee-extension Angle-specific Torques.

Authors:  B L Arnold; D H Perrin; E V Hellwig
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

Review 3.  Strength and power assessment. Issues, controversies and challenges.

Authors:  P Abernethy; G Wilson; P Logan
Journal:  Sports Med       Date:  1995-06       Impact factor: 11.136

4.  Reliability of lower extremity strength measures in persons with chronic stroke.

Authors:  Janice J Eng; C Maria Kim; Donna L Macintyre
Journal:  Arch Phys Med Rehabil       Date:  2002-03       Impact factor: 3.966

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.