AIM: In addition to planar parathyroid scintigraphy, SPECT and image fusion with CT/MR improve adenoma detection in primary hyperparathyroidism (pHPT). This study evaluated the use of a hybrid SPECT-CT device concerning image fusion and attenuation correction (AC). PATIENTS,
METHODS: The data of 26 patients with pHPT, preoperatively examined by (99m)Tc-sestamibi dual-phase scintigraphy plus SPECT-CT (low-dose CT), was retrospectively evaluated by two observers in a consensus reading. The images of planar scintigraphy, non-attenuation corrected SPECT (SPECT(NAC)), attenuation corrected SPECT (SPECT(AC)) and SPECT(AC)-CT were interpreted and compared to the results of surgery. The effect of AC on focus intensity was semiquantified by determination of the tumor-to-background (TB) ratio for SPECT(AC) and SPECT(NAC). Finally, the TB(AC)/TB(NAC)-ratio was calculated for each focus and correlated to the distance of a focus from the body surface.
RESULTS: 20/26 (77%) patients were positive in planar scintigraphy. One focus was detected by SPECT only. AC of SPECT-data increased image contrast but had no impact on the detection rate. Additional SPECT(AC)-CT image fusion facilitated the localization of three mediastinal foci. In the semiquantitative analysis an increase in TB after AC was observed, although there was no strong correlation between depth of the focus (16-60 mm) and the TB(AC)/TB(NAC)-ratio (r = 0.213, p = 0.353).
CONCLUSION: The detection rate of planar scintigraphy is only slightly improved by SPECT imaging. Due to the low spatial resolution of the CT component, the benefit of image fusion is limited to mediastinal foci. However, as TB and image contrast is measurably improved after AC there is a potential to improve the sensitivity of parathyroid SPECT.

Entities:  

Mesh:

Year:  2007        PMID: 17299650

Source DB:  PubMed          Journal:  Nuklearmedizin        ISSN: 0029-5566            Impact factor:   1.379


  5 in total

Review 1.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 2.  Imaging for primary hyperparathyroidism--an evidence-based analysis.

Authors:  Radu Mihai; Dietmar Simon; Per Hellman
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

3.  Actual role of color-doppler high-resolution neck ultrasonography in primary hyperparathyroidism: a clinical review and an observational study with a comparison of 99mTc-sestamibi parathyroid scintigraphy.

Authors:  Giovanni Mariano Vitetta; Alberto Ravera; Giovanni Mensa; Luca Fuso; Pierluigi Neri; Alessandro Carriero; Stefano Cirillo
Journal:  J Ultrasound       Date:  2018-10-24

Review 4.  Acquisition parameters for oncologic imaging with a new SPECT/multislice CT scanner.

Authors:  Rodolfo Núñez; William D Erwin; Richard E Wendt; Anne Stachowiak; Martha Mar; Donna Stevens; John E Madewell; Henry W Yeung; Homer A Macapinlac
Journal:  Mol Imaging Biol       Date:  2010-01-05       Impact factor: 3.488

5.  Comparison of five parathyroid scintigraphic protocols.

Authors:  Virpi Tunninen; Pekka Varjo; Jukka Schildt; Aapo Ahonen; Tomi Kauppinen; Irina Lisinen; Anu Holm; Hannu Eskola; Marko Seppänen
Journal:  Int J Mol Imaging       Date:  2013-01-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.