Literature DB >> 17296231

A new color vision test to differentiate congenital and acquired color vision defects.

Young Joo Shin1, Kyu Hyung Park, Jeong-Min Hwang, Won Ryang Wee, Jin Hak Lee.   

Abstract

PURPOSE: To investigate the efficacy of a novel computer-controlled color test for the differentiation of congenital and acquired color vision deficiency.
DESIGN: Observational cross-sectional study. PARTICIPANTS: Thirty-one patients with congenital color vision deficiency and 134 patients with acquired color vision deficiency with a Snellen visual acuity better than 20/30 underwent an ophthalmologic examination including the Ishihara color test, Hardy-Rand-Rittler test, Nagel anomaloscopy, and the Seohan computerized hue test between June, 2003, and January, 2004.
METHODS: To investigate the type of color vision defect, a graph of the Seohan computerized hue test was divided into 4 quadrants and error scores in each quadrant were summated. The ratio between the sums of error scores of quadrants I and III (Q1+Q3) and those of quadrants II and IV (Q2+Q4) was calculated. MAIN OUTCOME MEASURES: Error scores and ratio in quadrant analysis of the Seohan computerized hue test.
RESULTS: The Seohan computerized hue test showed that the sum of Q2+Q4 was significantly higher than the sum of Q1+Q3 in congenital color vision deficiency (P<0.01, paired t test) and that the sum of Q2+Q4 was significantly lower than the sum of Q1+Q3 in acquired color vision deficiency (P<0.01, paired t test). In terms of discriminating congenital and acquired color vision deficiency, the ratio in quadrant analysis had 93.3% sensitivity and 98.5% specificity with a reference value of 1.5 by the Seohan computerized hue test (95% confidence interval).
CONCLUSIONS: The quadrant analysis and ratio of (Q2+Q4)/(Q1+Q3) using the Seohan computerized hue test effectively differentiated congenital and acquired color vision deficiency.

Entities:  

Mesh:

Year:  2007        PMID: 17296231     DOI: 10.1016/j.ophtha.2006.10.030

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  2 in total

1.  Age-corrected reference values for the Heidelberg multi-color anomaloscope.

Authors:  Florian Rüfer; Benno Sauter; Alexa Klettner; Katja Göbel; Josef Flammer; Carl Erb
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-17       Impact factor: 3.117

2.  Acquired dyschromatopsia in acute myelocytic leukaemia.

Authors:  Mohammed Ziaei; Graham E Holder; Mostafa A Elgohary; Fion D Bremner
Journal:  Doc Ophthalmol       Date:  2013-09-20       Impact factor: 2.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.