Literature DB >> 17296198

Significance of hip rotation on measurement of 'Tip Apex Distance' during fixation of extracapsular proximal femoral fractures.

A J Shyam Kumar1, V N Parmar, S Kolpattil, S Humad, S C Williams, W M Harper.   

Abstract

UNLABELLED: The Tip Apex Distance (TAD) is defined as the sum of the distance, in millimetres, from the tip of the lag screw to the apex of the femoral head, as measured on an antero-posterior radiograph and lateral radiograph, after correction has been made for magnification. The relationship between the degree of rotation of the hip joint and its implication on measuring TAD during fixation of a proximal femoral fracture was studied. This relationship has not been previously explored in the English literature. This study involved radiographs of a lag screw placed in a synthetic femur specimen taken in neutral and varying degrees of rotation and adduction/abduction. The lag screw was placed anteriorly in the femoral head. Measurements were taken for each radiograph after correction for magnification.
RESULTS: Statistical analysis between measurements showed statistically significant differences (P<0.05) of TAD in AP and lateral (abduction and adduction) views. A graph to show the relationship between hip rotation and TAD was conducted and demonstrates a linear correlation.
CONCLUSION: If an anteriorly placed hip screw is not seen to be breaching the articular surface on a view taken in internal rotation, the screw is definitely not in the joint. Beware of a hip screw appearing very close to the joint surface on a view taken in external rotation or abduction as it could be within the joint. The converse may apply to a posteriorly placed screw.

Entities:  

Mesh:

Year:  2007        PMID: 17296198     DOI: 10.1016/j.injury.2006.12.002

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  7 in total

1.  Assessing Wire Navigation Performance in the Operating Room.

Authors:  Leah K Taylor; Geb W Thomas; Matthew D Karam; Clarence D Kreiter; Donald D Anderson
Journal:  J Surg Educ       Date:  2016-05-12       Impact factor: 2.891

2.  Radiographic quantification of dynamic hip screw migration.

Authors:  Laurent Audigé; Flurin Cagienard; Christoph Martin Sprecher; Norbert Suhm; Marc Andreas Müller
Journal:  Int Orthop       Date:  2013-10-22       Impact factor: 3.075

3.  Developing an objective assessment of surgical performance from operating room video and surgical imagery.

Authors:  Leah K Taylor; Geb W Thomas; Matthew D Karam; Clarence D Kreiter; Donald D Anderson
Journal:  IISE Trans Healthc Syst Eng       Date:  2018-02-08

4.  What is the relevance of the tip-apex distance as a predictor of lag screw cut-out?

Authors:  Jérôme M Goffin; Paul J Jenkins; Rishikesan Ramaesh; Pankaj Pankaj; A Hamish Simpson
Journal:  PLoS One       Date:  2013-08-28       Impact factor: 3.240

5.  The Scaphoid Safe Zone: A Radiographic Simulation Study to Prevent Cortical Perforation Arising from Different Views.

Authors:  Qi Quan; Lei Hong; Biao Chang; Ruoxi Liu; Yun Zhu; Jiang Peng; Qing Zhao; Shibi Lu
Journal:  PLoS One       Date:  2017-01-23       Impact factor: 3.240

6.  A review of tip apex distance in dynamic hip screw fixation of osteoporotic hip fractures.

Authors:  Imran Haruna Abdulkareem
Journal:  Niger Med J       Date:  2012-10

7.  The importance of surgical education in the accuracy of implant placement during hip fracture fixation.

Authors:  Vinay Parmar; A J Shyam Kumar
Journal:  J Orthop Traumatol       Date:  2009-03-13
  7 in total