Literature DB >> 17295797

Methodological aspects of exhaled nitric oxide measurements in infants.

Carmelo Gabriele1, Els C van der Wiel, Eveline M Nieuwhof, Henriette A Moll, Peter J F M Merkus, Johan C de Jongste.   

Abstract

Guidelines for the measurement of fractional exhaled nitric oxide (FE(NO)) recommend refraining from lung function tests (LFT) and certain foods and beverages before performing FE(NO) measurements, as they may lead to transiently altered FE(NO) levels. Little is known of such factors in infants. The aim of the present study was to evaluate whether forced expiratory maneuvers, sedation, nasal contamination, and breastfeeding affect FE(NO) values in infants. FE(NO) was measured off-line during tidal breathing by means of a facemask covering nose and mouth. FE(NO) measurements were performed in 45 sedated infants (mean age 12.1 months) who underwent LFT because of airway diseases and in 83 unsedated healthy infants (mean age 4.3 months). In infants with airway diseases, no difference was found in FE(NO) values before and 5 min after LFT (n = 19 infants, p = 0.7) and FE(NO) values before sedation did not differ from FE(NO) values during sedation (n = 10 infants, p = 0.2). Oral FE(NO) values were significantly lower than mixed (nasal + oral) FE(NO) (n = 42 infants, p < 0.001). FE(NO) values before and 5 min after breastfeeding were not different (n = 11 healthy infants, p = 0.57). The short-term reproducibility in healthy infants (n = 54) was satisfactory (intraclass correlation coefficient = 0.94). We conclude that, in infants with airway diseases, LFT prior to FE(NO) measurement did not influence FE(NO) values and FE(NO) values did not change after sedation. Oral FE(NO) values were significantly lower than mixed (oral + nasal) FE(NO), and breastfeeding did not influence FE(NO). Short-term reproducibility in awake healthy infants was good.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17295797     DOI: 10.1111/j.1399-3038.2006.00472.x

Source DB:  PubMed          Journal:  Pediatr Allergy Immunol        ISSN: 0905-6157            Impact factor:   6.377


  2 in total

1.  Exhaled nitric oxide and urinary EPX levels in infants: a pilot study.

Authors:  Fredrik Carlstedt; Dagmara Lazowska; Carl-Gustaf Bornehag; Anna-Carin Olin; Mikael Hasselgren
Journal:  Clin Mol Allergy       Date:  2011-05-16

2.  Exhaled nitric oxide measurements in the first 2 years of life: methodological issues, clinical and epidemiological applications.

Authors:  Carmelo Gabriele; Fernando M de Benedictis; Johan C de Jongste
Journal:  Ital J Pediatr       Date:  2009-07-20       Impact factor: 2.638

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.