Literature DB >> 17295395

Gadobenate dimeglumine as a contrast agent for MRI of the mouse liver.

Yusuke Inoue1, Kohki Yoshikawa, Yukihiro Nomura, Kiyoko Izawa, Morio Shimada, Arinobu Tojo, Kuni Ohtomo.   

Abstract

We investigated the characteristics and utility of gadobenate dimeglumine (Gd-BOPTA) for MRI of the mouse liver. Mice were imaged under isoflurane anesthesia using a T(1)-weighted, three-dimensional fast low-angle shot (3D FLASH) sequence before and after intravenous or subcutaneous injection of Gd-BOPTA, and the time course of the contrast effect was examined. The appropriate dose for subcutaneous injection was determined visually, and the inter- and intra-observer reproducibilities in liver volumetry were evaluated with and without contrast injection. When mice were imaged sequentially before and after Gd-BOPTA injection and isoflurane anesthesia was maintained throughout the experiment, a long-lasting contrast effect was noted in the liver. Subcutaneous injection caused delayed, but favorable, enhancement. Washout from the liver was definitely accelerated in conscious mice in comparison with anesthetized mice. Visual evaluation indicated that a dose of 0.1 mmol/kg was appropriate for clear delineation of the entire liver margin, and the application of Gd-BOPTA significantly improved the inter- and intra-observer reproducibilities of liver volumetry. In conclusion, the intravenous or subcutaneous injection of Gd-BOPTA has a favorable contrast effect for the mouse liver, resulting in clear visualization of the liver border and improved reproducibility of liver volumetry. The possible influence of anesthesia on the pharmacokinetics of a contrast agent should be considered in determining the optimal scan timing.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17295395     DOI: 10.1002/nbm.1135

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  2 in total

1.  Long-term assessment of contrast effects of gadofluorine M and gadofluorine P in magnetic resonance imaging of mice.

Authors:  Fugeng Sheng; Yusuke Inoue; Shigeru Kiryu; Makoto Watanabe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-02       Impact factor: 2.374

2.  Distortion correction in whole-body imaging of live mice using a 1-Tesla compact magnetic resonance imaging system.

Authors:  Shigeru Kiryu; Yusuke Inoue; Yoshitaka Masutani; Tomoyuki Haishi; Kohki Yoshikawa; Makoto Watanabe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-06-30       Impact factor: 2.374

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.