Literature DB >> 17293202

Intrathoracic impedance monitoring to predict decompensated heart failure.

Claudia Ypenburg1, Jeroen J Bax, Ernst E van der Wall, Martin J Schalij, Lieselot van Erven.   

Abstract

Intrathoracic impedance measurement has been introduced in the InSync Sentry biventricular implantable cardioverter-defibrillator and may permit the early identification of pulmonary fluid accumulation secondary to left-sided heart failure (HF). An audible alarm (the OptiVol alert) can be triggered when the impedance index increases to greater than a predefined level of 60 Omega . day. The aim of this study was to evaluate the clinical value of the OptiVol alert and its prediction for decompensated HF. One hundred fifteen consecutive patients (mean New York Heart Association class 2.8 +/- 0.5, mean left ventricular ejection fraction 26 +/- 8%) who received InSync Sentry biventricular implantable cardioverter-defibrillators were included. When presenting with the OptiVol alert, current hemodynamic status was evaluated. During follow-up (mean 9 +/- 5 months), there were 45 presentations with the OptiVol alert in 30 patients. Clinical signs and symptoms of HF were present in only 15 patients (33%), whereas in the remaining patients, clinical signs of HF were absent (p <0.05). Receiver-operating characteristic curve analysis showed that increasing the threshold for the OptiVol alert provided a substantial increase in specificity for the detection of HF, with the optimal cut-off value identified at 120 Omega . day, yielding sensitivity of 60% and specificity of 73%. In conclusion, intrathoracic impedance measurement as present in the InSync Sentry biventricular implantable cardioverter-defibrillator may be a useful tool for monitoring pulmonary fluid status. The proposed threshold for the OptiVol alert of 60 Omega. day is very sensitive but not specific for the assessment of HF; adjustment of threshold settings may yield a superior balance between sensitivity and specificity.

Entities:  

Mesh:

Year:  2007        PMID: 17293202     DOI: 10.1016/j.amjcard.2006.08.066

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  31 in total

1.  Remote heart failure monitoring.

Authors:  William T Abraham
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-10

2.  Predictive impact of the decreasing rate of intrathoracic impedance in worsening chronic heart failure.

Authors:  Shinya Yamada; Hitoshi Suzuki; Yoshiyuki Kamiyama; Shu-ichi Saitoh; Yasuchika Takeishi
Journal:  J Interv Card Electrophysiol       Date:  2014-03-22       Impact factor: 1.900

Review 3.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

4.  A mixed methods study of symptom perception in patients with chronic heart failure.

Authors:  Barbara Riegel; Victoria Vaughan Dickson; Christopher S Lee; Marguerite Daus; Julia Hill; Elliane Irani; Solim Lee; Joyce W Wald; Stephen T Moelter; Lisa Rathman; Megan Streur; Foster Osei Baah; Linda Ruppert; Daniel R Schwartz; Alfred Bove
Journal:  Heart Lung       Date:  2018-01-03       Impact factor: 2.210

Review 5.  Implantable cardiovascular sensors and computers: interventional heart failure strategies.

Authors:  Sakima A Smith; William T Abraham
Journal:  Curr Cardiol Rep       Date:  2012-10       Impact factor: 2.931

Review 6.  Implantable Hemodynamic Monitoring in Ambulatory Heart Failure: Who, When, Why, How?

Authors:  Akshay S Desai
Journal:  Curr Cardiol Rep       Date:  2015-12       Impact factor: 2.931

7.  Influence of lung volume, fluid and capillary recruitment during positional changes and exercise on thoracic impedance in heart failure.

Authors:  Chul-Ho Kim; Matthew A Fuglestad; Maile L Ceridon Richert; Win K Shen; Bruce D Johnson
Journal:  Respir Physiol Neurobiol       Date:  2014-08-14       Impact factor: 1.931

Review 8.  How to improve outcomes: should we put more emphasis on programming and medical care and less on patient selection?

Authors:  Laszlo Buga
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

9.  Therapeutic implications of implantable device-based monitoring of patients with heart failure.

Authors:  Eric Popjes; John P Boehmer
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-09

Review 10.  Cardiac resynchronization therapy in heart failure patients with atrial fibrillation.

Authors:  Maurizio Gasparini; François Regoli; Paola Galimberti; Carlo Ceriotti; Alessio Cappelleri
Journal:  Europace       Date:  2009-11       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.