Literature DB >> 17281598

Common mode noise cancellation for electrically non-contact ECG measurement system on a chair.

Ko Keun Kim1, Yong Kyu Lim, Kwang Suk Park.   

Abstract

Electrically non-contact ECG measurement system on a chair can be applied to a number of various fields for continuous health monitoring in daily life. However, the body is floated electrically for this system due to the capacitive electrodes and the floated body is very sensitive to the external noises or motion artifacts which affect the measurement system as the common mode noise. In this paper, the Driven-Seat-Ground circuit similar to the Driven-Right-Leg circuit is proposed to reduce the common mode noise. The analysis of this equivalent circuit is performed and the output signal waveforms are compared between with Driven-Seat-Ground and with capacitive ground. As the results, the Driven-Seat-Ground circuit improves significantly the properties of the fully capacitive ECG measurement system as the negative feedback.

Year:  2005        PMID: 17281598     DOI: 10.1109/IEMBS.2005.1615828

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.

Authors:  Hong Ji Lee; Su Hwan Hwang; Hee Nam Yoon; Won Kyu Lee; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2015-05-14       Impact factor: 3.576

2.  Characterization of Textile-Insulated Capacitive Biosensors.

Authors:  Charn Loong Ng; Mamun Bin Ibne Reaz
Journal:  Sensors (Basel)       Date:  2017-03-12       Impact factor: 3.576

3.  Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability.

Authors:  Ji-Jer Huang; Zhe-Lin Cai
Journal:  J Healthc Eng       Date:  2020-07-08       Impact factor: 2.682

4.  A Novel Analog Front End with Voltage-Dependent Input Impedance and Bandpass Amplification for Capacitive Biopotential Measurements.

Authors:  Hajime Nakamura; Yuichiro Sakajiri; Hiroshi Ishigami; Akinori Ueno
Journal:  Sensors (Basel)       Date:  2020-04-27       Impact factor: 3.576

5.  Non-Contact Measurements of Electrocardiogram and Cough-Associated Electromyogram from the Neck Using In-Pillow Common Cloth Electrodes: A Proof-of-Concept Study.

Authors:  Akira Takano; Hiroshi Ishigami; Akinori Ueno
Journal:  Sensors (Basel)       Date:  2021-01-26       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.