Wide FOV wedge prism endoscope.

Keri Kim1, Daeyoung Kim, Kiyoshi Matsumiya, Etsuko Kobayashi, Takeyoshi Dohi.   

Abstract

We.. have developed a novel robotic endoscope system. It can be used to observe a wide field of view without moving or bending the whole endoscope system. .. It consists of a rigid endoscope and two wedge prisms at the distal tip. Rotating each wedge prism respectively, we can change the direction of view. Accordingly it becomes possible to observe a wide field of view even in a small space, and suited to clinical uses because it does not damage body tissues or internal organs. .. Wedge prisms are designed to avoid vignetting which is caused by the refraction or the reflection at prisms. The endoscope has 10mm in diameter, and the drive unit is simply separable for the sterilization. In addition, since it has a simple and small drive unit, it does not obstruct surgeon or other surgery robots. The maximum movement of local field of view is 19degrees, and global field of view is 93degrees. In the evaluation experiment, we conformed that both of the image quality and the performance are acceptable.

Year:  2005        PMID: 17281566     DOI: 10.1109/IEMBS.2005.1615796

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

Authors:  Hiroki Kamiuchi; Ken Masamune; Kenta Kuwana; Takeyoshi Dohi; Keri Kim; Hiromasa Yamashita; Toshio Chiba
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-23       Impact factor: 2.924

2.  Actual state of EndActive ventricular endoscopy.

Authors:  Florian H Ebner; Bernhard Hirt; Jakob S Marquardt; Stephan Herlan; Marcos Tatagiba; Martin U Schuhmann
Journal:  Childs Nerv Syst       Date:  2011-08-18       Impact factor: 1.475

3.  Compound prism design principles, I.

Authors:  Nathan Hagen; Tomasz S Tkaczyk
Journal:  Appl Opt       Date:  2011-09-01       Impact factor: 1.980

4.  Improvement of arthroscopic surgical performance using a new wide-angle arthroscope in the surgical training.

Authors:  Jae-Man Kwak; Erica Kholinne; Maulik Gandhi; Arnold Adikrishna; Hanpyo Hong; Yucheng Sun; Kyoung-Hwan Koh; In-Ho Jeon
Journal:  PLoS One       Date:  2019-03-11       Impact factor: 3.240

5.  The Dimensionless Squared Jerk: An Objective Parameter That Improves Assessment of Hand Motion Analysis during Simulated Shoulder Arthroscopy.

Authors:  Erica Kholinne; Maulik J Gandhi; Arnold Adikrishna; Hanpyo Hong; Haewon Kim; Jaesung Hong; In-Ho Jeon
Journal:  Biomed Res Int       Date:  2018-07-11       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.