Literature DB >> 17281468

Design and implementation of High Performance Visual Stimulator for Brain Computer Interfaces.

V Jaganathan1, T M Srihari Mukesh, M Ramasubba Reddy.   

Abstract

An algorithm for implementing visual stimulators on generic computers has been developed for Brain Computer Interfaces (BCIs). It uses the hardware counter present in these systems to derive accurate timing. Simultaneous display of 20 patterns (e.g. 3×3 checkerboards) modulated at different frequencies is possible. The pattern used for stimulating the Steady State Visual Evoked Potential (SSVEP) can be changed with ease. The stimulators are evaluated using software counters. High accuracy (less than 0.73% error) and precision (0.1% coefficient of variation) is recorded for 20 patterns set with frequencies between 6 Hz and 15 Hz.

Entities:  

Year:  2005        PMID: 17281468     DOI: 10.1109/IEMBS.2005.1615698

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

Review 1.  A survey of stimulation methods used in SSVEP-based BCIs.

Authors:  Danhua Zhu; Jordi Bieger; Gary Garcia Molina; Ronald M Aarts
Journal:  Comput Intell Neurosci       Date:  2010-03-07

2.  Square or sine: finding a waveform with high success rate of eliciting SSVEP.

Authors:  Fei Teng; Yixin Chen; Aik Min Choong; Scott Gustafson; Christopher Reichley; Pamela Lawhead; Dwight Waddell
Journal:  Comput Intell Neurosci       Date:  2011-09-15

3.  Fully online multicommand brain-computer interface with visual neurofeedback using SSVEP paradigm.

Authors:  Pablo Martinez; Hovagim Bakardjian; Andrzej Cichocki
Journal:  Comput Intell Neurosci       Date:  2007
  3 in total