Literature DB >> 17278896

Predicting changes in dose distribution to tumor and normal tissue when correcting for heterogeneity in radiotherapy for lung cancer.

Daniel Chang1, Chihray Liu, James F Dempsey, Jatinder R Palta, Jill Kopea, Debbie Louis, Christopher Morris, Rahul Chopra, Kenneth R Olivier.   

Abstract

PURPOSES: The purposes of this study were to examine dose alterations to gross tumor volume (GTV) and lung using heterogeneity corrections and to predict the magnitude of these changes.
METHODS: Three separate conformal plans were generated for 37 patients with lung cancer: plan 1 corrected for heterogeneity, plan 2 did not correct for heterogeneity, and plan 3 used identical beams and monitor units from plan 2 but with heterogeneous calculations. Plans 1 and 2 were normalized to the 95% isodose line. Mean dose (MeanDGTV), maximum dose (MaxDGTV), and minimum dose (MinDGTV) to GTV and V20 were compared between plans 1 and 3. For each patient, the amount of lung in all beam paths of plan 3 was quantified by a density correction factor and correlated with the percent change.
RESULTS: The median percent change in MeanDGTV, MaxDGTV, and MinDGTV between plan 3 and plan 1 was -4.7% (-0.1% to -19.1%, P < 0.0001), -5.59% (0.16% to -31.86%, P < 0.0001), and -4.88% (2.90% to -24.88%, P < 0.0001), respectively. The median V20 difference was -1% (1% to -8%). The density correction factor correlated with larger differences in MeanDGTV on univariate analysis.
CONCLUSIONS: Heterogeneity correction lowers the dose to GTV by 5%. This difference can be correlated with the density correction factor.

Entities:  

Mesh:

Year:  2007        PMID: 17278896     DOI: 10.1097/01.coc.0000251222.36417.3b

Source DB:  PubMed          Journal:  Am J Clin Oncol        ISSN: 0277-3732            Impact factor:   2.339


  7 in total

1.  Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung.

Authors:  Rie Yamazaki; Rikiya Onimaru; Norio Katoh; Tetsuya Inoue; Takeshi Nishioka; Hiroki Shirato; Hiroyuki Date
Journal:  Radiol Phys Technol       Date:  2014-03-19

2.  Heterogeneous Versus Homogeneous Radiation Dose Calculations of Twice-Daily Fractionation in Small Cell Lung Carcinoma.

Authors:  Ryan Thibodeau; Hsin K Li; Sean Tanny; Ajeet Gajra; Jeffrey Bogart
Journal:  Cureus       Date:  2021-12-07

3.  Impact of tissue heterogeneity corrections in stereotactic body radiation therapy treatment plans for lung cancer.

Authors:  Tania De La Fuente Herman; Heather Gabrish; Terence S Herman; Maria T Vlachaki; Salahuddin Ahmad
Journal:  J Med Phys       Date:  2010-07

4.  Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer.

Authors:  Ying Xiao; Lech Papiez; Rebecca Paulus; Robert Timmerman; William L Straube; Walter R Bosch; Jeff Michalski; James M Galvin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-15       Impact factor: 7.038

5.  Evaluation of heterogeneity dose distributions for Stereotactic Radiotherapy (SRT): comparison of commercially available Monte Carlo dose calculation with other algorithms.

Authors:  Wataru Takahashi; Hideomi Yamashita; Naoya Saotome; Yoshio Iwai; Akira Sakumi; Akihiro Haga; Keiichi Nakagawa
Journal:  Radiat Oncol       Date:  2012-02-09       Impact factor: 3.481

6.  Stereotactic body radiotherapy for small lung tumors in the University of Tokyo Hospital.

Authors:  Hideomi Yamashita; Wataru Takahashi; Akihiro Haga; Satoshi Kida; Naoya Saotome; Keiichi Nakagawa
Journal:  Biomed Res Int       Date:  2014-07-07       Impact factor: 3.411

7.  Performance Evaluation of Algorithms in Lung IMRT: A comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms.

Authors:  T Verma; N K Painuly; S P Mishra; M Shajahan; N Singh; M L B Bhatt; N Jamal; M C Pant
Journal:  J Biomed Phys Eng       Date:  2016-09-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.