An iterative three-dimensional electron density imaging algorithm using uncollimated compton scattered x rays from a polyenergetic primary pencil beam.

Eric Van Uytven1, Stephen Pistorius, Richard Gordon.   

Abstract

X-ray film-screen mammography is currently the gold standard for detecting breast cancer. However, one disadvantage is that it projects a three-dimensional (3D) object onto a two-dimensional (2D) image, reducing contrast between small lesions and layers of normal tissue. Another limitation is its reduced sensitivity in women with mammographically dense breasts. Computed tomography (CT) produces a 3D image yet has had a limited role in mammography due to its relatively high dose, low resolution, and low contrast. As a first step towards implementing quantitative 3D mammography, which may improve the ability to detect and specify breast tumors, we have developed an analytical technique that can use Compton scatter to obtain 3D information of an object from a single projection. Imaging material with a pencil beam of polychromatic x rays produces a characteristic scattered photon spectrum at each point on the detector plane. A comparable distribution may be calculated using a known incident x-ray energy spectrum, beam shape, and an initial estimate of the object's 3D mass attenuation and electron density. Our iterative minimization algorithm changes the initially arbitrary electron density voxel matrix to reduce regular differences between the analytically predicted and experimentally measured spectra at each point on the detector plane. The simulated electron density converges to that of the object as the differences are minimized. The reconstruction algorithm has been validated using simulated data produced by the EGSnrc Monte Carlo code system. We applied the imaging algorithm to a cylindrically symmetric breast tissue phantom containing multiple inhomogeneities. A preliminary ROC analysis scores greater than 0.96, which indicate that under the described simplifying conditions, this approach shows promise in identifying and localizing inhomogeneities which simulate 0.5 mm calcifications with an image voxel resolution of 0.25 cm and at a dose comparable to mammography.

Entities:  

Mesh:

Year:  2007        PMID: 17278511     DOI: 10.1118/1.2400835

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Compton scatter imaging: A promising modality for image guidance in lung stereotactic body radiation therapy.

Authors:  Gage Redler; Kevin C Jones; Alistair Templeton; Damian Bernard; Julius Turian; James C H Chu
Journal:  Med Phys       Date:  2018-02-07       Impact factor: 4.071

2.  Snapshot 2D tomography via coded aperture x-ray scatter imaging.

Authors:  Kenneth P MacCabe; Andrew D Holmgren; Martin P Tornai; David J Brady
Journal:  Appl Opt       Date:  2013-07-01       Impact factor: 1.980

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.