Literature DB >> 17278505

Technical note: a deformable phantom for dynamic modeling in radiation therapy.

Rojano Kashani1, Kwok Lam, Dale Litzenberg, James Balter.   

Abstract

A deformable phantom was developed to aid in quality assurance for dynamic imaging and targeting techniques in radiation therapy. Made of simple materials combined with standard components for imaging and motion experiments, this phantom can be relatively easily constructed and used for both diagnostic imaging and dosimetry. Repeat imaging studies indicate that the phantom meets criteria of relative attenuation, deformation, and reproducibility of configuration, necessary for quality assurance of radiographic and tomographic targeting.

Entities:  

Mesh:

Year:  2007        PMID: 17278505     DOI: 10.1118/1.2400612

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study.

Authors:  Rojano Kashani; Martina Hub; James M Balter; Marc L Kessler; Lei Dong; Lifei Zhang; Lei Xing; Yaoqin Xie; David Hawkes; Julia A Schnabel; Jamie McClelland; Sarang Joshi; Quan Chen; Weiguo Lu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  An externally and internally deformable, programmable lung motion phantom.

Authors:  Yam Cheung; Amit Sawant
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

4.  A novel deformable lung phantom with programably variable external and internal correlation.

Authors:  Maida Ranjbar; Pouya Sabouri; Carlo Repetto; Amit Sawant
Journal:  Med Phys       Date:  2019-04-22       Impact factor: 4.071

5.  Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator.

Authors:  Yuanyuan Ge; Ricky T O'Brien; Chun-Chien Shieh; Jeremy T Booth; Paul J Keall
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

6.  Dynamic MRI of grid-tagged hyperpolarized helium-3 for the assessment of lung motion during breathing.

Authors:  Jing Cai; Ke Sheng; Stanley H Benedict; Paul W Read; James M Larner; John P Mugler; Eduard E de Lange; Gordon D Cates; G Wilson Miller
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

7.  Development of a deformable lung phantom for the evaluation of deformable registration.

Authors:  Jina Chang; Tae-Suk Suh; Dong-Soo Lee
Journal:  J Appl Clin Med Phys       Date:  2010-01-28       Impact factor: 2.102

8.  Deformable image registration with inclusion of autodetected homologous tissue features.

Authors:  Qingsong Zhu; Jia Gu; Yaoqin Xie
Journal:  ScientificWorldJournal       Date:  2012-04-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.