Literature DB >> 17277971

Corrosion resistance studies on grain-boundary etched drug-eluting stents.

Ralf Rettig1, Julia Kunze, Michael Stöver, Erich Wintermantel, Sannakaisa Virtanen.   

Abstract

In this paper we compare the influence of different microstructures on the corrosion resistance of new drug-eluting stainless steel stents, which have been produced by grain-boundary-selective electrochemical etching processes. The morphology of the stent surfaces was analysed by scanning electron microscopy (SEM), and the surface composition was investigated with Auger electron spectroscopy (AES) as well as with energy dispersive X-ray analysis (EDX). The passivity of the different microstructured stents was studied by cyclovoltammetry in Ringer solution. Release of nickel and chromium was assessed after potentiostatic experiments in Ringer solution by analysing the collected electrolyte with AAS. For stents produced by different two-step etching procedures bringing about ideal morphologies regarding the mechanical and biological properties of the surface, no significant differences in the passivation behaviour could be observed. A two-step process using first nitric acid and oxalic acid in a second step produces stent surfaces with very good corrosion properties: electrochemical analysis shows that the range of stable passivity is the same as for conventional stent surfaces, and low rates of nickel and chromium release are observed. The etching procedures do not seem to change the surface oxide layer composition.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17277971     DOI: 10.1007/s10856-007-0152-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  Rapamycin eluting stent: the onset of a new era in interventional cardiology.

Authors:  P W Serruys; E Regar; A J Carter
Journal:  Heart       Date:  2002-04       Impact factor: 5.994

2.  Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study.

Authors:  R Hoffmann; G S Mintz; G R Dussaillant; J J Popma; A D Pichard; L F Satler; K M Kent; J Griffin; M B Leon
Journal:  Circulation       Date:  1996-09-15       Impact factor: 29.690

3.  Electrochemistry of galvanic couples between carbon and common metallic biomaterials in the presence of crevices.

Authors:  R A Silva; M A Barbosa; G M Jenkins; I Sutherland
Journal:  Biomaterials       Date:  1990-07       Impact factor: 12.479

4.  Predictors of diffuse and aggressive intra-stent restenosis.

Authors:  S L Goldberg; A Loussararian; J De Gregorio; C Di Mario; R Albiero; A Colombo
Journal:  J Am Coll Cardiol       Date:  2001-03-15       Impact factor: 24.094

Review 5.  State of the art in coronary intervention.

Authors:  David R Holmes
Journal:  Am J Cardiol       Date:  2003-02-06       Impact factor: 2.778

6.  Initial and long-term outcome of 354 patients after coronary balloon angioplasty of total coronary artery occlusions.

Authors:  M R Bell; P B Berger; J F Bresnahan; G S Reeder; K R Bailey; D R Holmes
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

Review 7.  Drug-eluting stents in vascular intervention.

Authors:  Rossella Fattori; Tommaso Piva
Journal:  Lancet       Date:  2003-01-18       Impact factor: 79.321

8.  Restenosis after successful coronary angioplasty in patients with single-vessel disease.

Authors:  P P Leimgruber; G S Roubin; J Hollman; G A Cotsonis; B Meier; J S Douglas; S B King; A R Gruentzig
Journal:  Circulation       Date:  1986-04       Impact factor: 29.690

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.