Literature DB >> 17277042

Using continuous glucose monitoring to measure the frequency of low glucose values when using biphasic insulin aspart 30 compared with biphasic human insulin 30: a double-blind crossover study in individuals with type 2 diabetes.

Paul G McNally1, John D Dean, Andrew D Morris, Peter D Wilkinson, Gerhard Compion, Simon R Heller.   

Abstract

OBJECTIVE: Rapid-acting insulin analogs in basal-bolus regimens can reduce nocturnal hypoglycemia, so it is conceivable that twice-daily biphasic insulin analogs might reduce hypoglycemia in patients with insulin-treated type 2 diabetes. We used a continuous glucose monitoring system (CGMS) and self-reported episodes to investigate differences in the frequency of low glucose values in patients with type 2 diabetes, using either biphasic insulin aspart 30 (BIAsp 30) or biphasic human insulin 30 (BHI 30). RESEARCH DESIGN AND METHODS: This was a double-blind, two-period, crossover trial involving 160 subjects. After 8 weeks' run-in, subjects were randomized to the first of two 16-week treatment periods.
RESULTS: No differences in overall incidence of low interstitial glucose (IG) were found. Twenty-four-hour plots of CGMS showed low IG was more frequent at night than during the day and was unrecognized by patients. At night, subjects spent significantly less time (percentage of total CGMS recorded) with IG <3.5 and <2.5 mmol/l during BIAsp 30 than during BHI 30 treatment, respectively (<3.5 mmol/l: 6.36 vs. 7.93% [mean], 0.67 vs. 2.43% [median], P = 0.018; <2.5 mmol/l: 2.35 vs. 2.86% [mean], 0 vs. 0% [median], P = 0.0467). No treatment difference in A1C was observed.
CONCLUSIONS: Overall rates of low glucose over 24 h were not different but were twice as frequent at night than during the day in individuals with type 2 diabetes. Compared with BHI 30, BIAsp 30 was associated with similar low IG readings over 24 h but with fewer nocturnal episodes and less self-reported nocturnal hypoglycemia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17277042     DOI: 10.2337/dc06-1328

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  21 in total

Review 1.  Closing the Loop.

Authors:  Revital Nimri; Nathan Murray; Alexander Ochs; Jordan E Pinsker; Eyal Dassau
Journal:  Diabetes Technol Ther       Date:  2017-02       Impact factor: 6.118

2.  Recurrent Hypoglycemia Exacerbates Cerebral Ischemic Damage in Diabetic Rats via Enhanced Post-Ischemic Mitochondrial Dysfunction.

Authors:  Vibha Shukla; Perry Fuchs; Allen Liu; Charles H Cohan; Chuanhui Dong; Clinton B Wright; Miguel A Perez-Pinzon; Kunjan R Dave
Journal:  Transl Stroke Res       Date:  2018-03-22       Impact factor: 6.829

Review 3.  How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?

Authors:  Ramzi A Ajjan
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

4.  TREATMENT OF TYPE 2 DIABETES WITH BIPHASIC INSULIN ANALOGUES.

Authors:  Ali A Rizvi
Journal:  Eur Med J Diabetes       Date:  2016-10-27

Review 5.  Ischemic brain injury in diabetes and endoplasmic reticulum stress.

Authors:  Ashish K Rehni; Sunjoo Cho; Kunjan R Dave
Journal:  Neurochem Int       Date:  2021-11-01       Impact factor: 3.921

6.  Hypoglycemia in Type 2 Diabetes--More Common Than You Think: A Continuous Glucose Monitoring Study.

Authors:  Richa Redhu Gehlaut; Godwin Y Dogbey; Frank L Schwartz; Cynthia R Marling; Jay H Shubrook
Journal:  J Diabetes Sci Technol       Date:  2015-04-27

Review 7.  Biphasic insulin aspart in type 2 diabetes mellitus: an evidence-based medicine review.

Authors:  S C L Gough; J Tibaldi
Journal:  Clin Drug Investig       Date:  2007       Impact factor: 2.859

8.  Initiating or switching to biphasic insulin aspart 30/70 therapy in subjects with type 2 diabetes mellitus. An observational study.

Authors:  Leif Breum; Thomas Almdal; Pia Eiken; Per Lund; Erik Christiansen
Journal:  Rev Diabet Stud       Date:  2008-11-10

Review 9.  Systematic review: comparative effectiveness and safety of premixed insulin analogues in type 2 diabetes.

Authors:  Rehan Qayyum; Shari Bolen; Nisa Maruthur; Leonard Feldman; Lisa M Wilson; Spyridon S Marinopoulos; Padmini Ranasinghe; Muhammed Amer; Eric B Bass
Journal:  Ann Intern Med       Date:  2008-09-15       Impact factor: 25.391

10.  Feasibility and acceptability of continuous glucose monitoring and accelerometer technology in exercising individuals with type 2 diabetes.

Authors:  Nancy A Allen; Cynthia S Jacelon; Stuart R Chipkin
Journal:  J Clin Nurs       Date:  2009-02       Impact factor: 3.036

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.