Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients.

Sachinder Singh Hans1, Olan Jareunpoon.   

Abstract

OBJECTIVE: This study attempted to correlate neurologic changes in awake patients undergoing carotid endarterectomy (CEA) under cervical block anesthesia (CBA) with electroencephalography (EEG) and measurement of carotid artery stump pressure (SP).
METHODS: Continuous EEG and SP monitoring was measured prospectively in 314 consecutive patients undergoing CEA between April 1, 2003, and July 30, 2006, under CBA. Indications for CEA were asymptomatic 70% to 99% internal carotid artery stenosis in 242 (77.1%), transient ischemic attacks (including transient monocular blindness) in 45 (14.3%), and prior stroke in 27 (8.6%). Mean common carotid artery pressure before clamping, mean SP after carotid clamping, and intraarterial pressure were continuously monitored in all patients. An indwelling shunt was placed when neurologic events (contralateral motor weakness, aphasia, loss of consciousness, or seizures) occurred, regardless of SP or EEG changes.
RESULTS: Shunt placement was necessary because of neurologic changes in 10% (32/314) of all CEAs performed under CBA. Only 3 patients (1.4%) of 216 required shunt placement if SP was 50 mm Hg or more, vs 29 (29.6%) of 98 if SP was less than 50 mm Hg (P < .00001; sensitivity, 29.8%; specificity, 98.6%). In patients with SP of 40 mm Hg or more, 7 (2.6%) of 270 required shunt placement, vs 25 (56.8%) of 44 if SP was less than 40 mm Hg (P < .00001; sensitivity, 56.8%; specificity, 97.4%). Ischemic EEG changes were observed in 19 (59.4%) of 32 patients (false-negative rate, 40.6%) requiring shunt placement under CBA. Three patients had false-positive EEG results and did not require shunt placement (false-positive rate, 1.0%). The perioperative stroke/death rate was 4 (1.2%) in 314. All strokes occurred after surgery and were unrelated to cerebral ischemia or lack of shunt placement.
CONCLUSIONS: Ten percent of patients required a shunt placement during CEA under CBA. Shunt placement was necessary in 56.8% of patients with SP less than 40 mm Hg. EEG identified cerebral ischemia in only 59.4% of patients needing shunt placement, with a false-positive rate of 1.0% and a false-negative rate of 40.6%. Both SP and EEG as a guide to shunt placement have poor sensitivity. Intraoperative monitoring of the awake patients under regional anesthesia (CBA) is the most sensitive and specific method to identify patients requiring shunt placement.

Entities:  

Mesh:

Year:  2007        PMID: 17275248     DOI: 10.1016/j.jvs.2006.11.035

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  22 in total

Review 1.  [Anesthesia for carotid artery surgery. Is there a gold standard?].

Authors:  T Rössel; R J Litz; A R Heller; T Koch
Journal:  Anaesthesist       Date:  2008-02       Impact factor: 1.041

Review 2.  [Complications after supra-aortic reconstruction].

Authors:  T Bürger
Journal:  Chirurg       Date:  2015-07       Impact factor: 0.955

3.  Ocular blood flow by laser speckle flowgraphy to detect cerebral ischemia during carotid endarterectomy.

Authors:  Yasushi Motoyama; Hironobu Hayashi; Hideaki Kawanishi; Kohsuke Tsubaki; Tsunenori Takatani; Yoshiaki Takamura; Masashi Kotsugi; Taekyun Kim; Shuichi Yamada; Ichiro Nakagawa; Young-Su Park; Masahiko Kawaguchi; Hiroyuki Nakase
Journal:  J Clin Monit Comput       Date:  2020-02-07       Impact factor: 2.502

4.  Impact of general versus local anesthesia on early postoperative cognitive dysfunction following carotid endarterectomy: GALA Study Subgroup Analysis.

Authors:  Christian Friedrich Weber; Hannah Friedl; Michael Hueppe; Gudrun Hintereder; Thomas Schmitz-Rixen; Bernhard Zwissler; Dirk Meininger
Journal:  World J Surg       Date:  2009-07       Impact factor: 3.352

5.  Protamine reduces bleeding complications associated with carotid endarterectomy without increasing the risk of stroke.

Authors:  David H Stone; Brian W Nolan; Andres Schanzer; Philip P Goodney; Robert A Cambria; Donald S Likosky; Daniel B Walsh; Jack L Cronenwett
Journal:  J Vasc Surg       Date:  2010-01-04       Impact factor: 4.268

6.  [Neuromonitoring and neuroprotection in cardiac anaesthesia. Nationwide survey conducted by the Cardiac Anaesthesia Working Group of the German Society of Anaesthesiology and Intensive Care Medicine].

Authors:  G Erdös; I Tzanova; U Schirmer; J Ender
Journal:  Anaesthesist       Date:  2009-03       Impact factor: 1.041

7.  Quantitative EEG correlates of low cerebral perfusion in severe stroke.

Authors:  Jennifer Diedler; Marek Sykora; Thomas Bast; Sven Poli; Roland Veltkamp; Patricio Mellado; Thorsten Steiner; André Rupp
Journal:  Neurocrit Care       Date:  2009       Impact factor: 3.210

8.  Is Near-Infrared Spectroscopy a Reliable Method to Evaluate Clamping Ischemia during Carotid Surgery?

Authors:  Luciano Pedrini; Filippo Magnoni; Luigi Sensi; Emilio Pisano; Maria Sandra Ballestrazzi; Maria Rosaria Cirelli; Alessandro Pilato
Journal:  Stroke Res Treat       Date:  2011-11-09

9.  Protocol for electrophysiological monitoring of carotid endarterectomies.

Authors:  Hong Liu; Anthony M Di Giorgio; Eric S Williams; William Evans; Michael J Russell
Journal:  J Biomed Res       Date:  2010-11

10.  Selective shunt during carotid endarterectomy using routine awake test with respect to a lower shunt rate.

Authors:  Jayun Cho; Kyung Keun Lee; Woo-Sung Yun; Hyung-Kee Kim; Yang-Ha Hwang; Seung Huh
Journal:  J Korean Surg Soc       Date:  2013-03-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.