Literature DB >> 17275150

Knee kinematics in functional activities seven years after total knee arthroplasty.

Mariëtta L van der Linden1, Philip J Rowe, Christine M Myles, Richard Burnett, Richard W Nutton.   

Abstract

BACKGROUND: Detailed knowledge of knee kinematics during functional activities is lacking in current studies on the long-term outcome of total knee replacement surgery. The aim of this study was to assess functional knee kinematics using flexible electrogoniometry in patients seven years after unilateral primary total knee arthroplasty for osteoarthritis.
METHODS: The knee joint functional movement of a cohort of patients (n=19) with knee osteoarthritis was assessed using electrogoniometry before surgery and 18-24 months and seven years after total knee surgery. The mean age of the patients (11 women and 8 men) at the time of the pre-surgery assessment was 67 years old (SD 8.0). Patient function was also assessed using the Knee Society Score and WOMAC osteoarthritis Index.
FINDINGS: The function components of the Knee Society and WOMAC scores were significantly decreased at seven years compared to 18-24 months after surgery (both P<0.05). However, the majority of the functional knee flexion values derived from electrogoniometry did not decrease. Seven years after surgery, knee excursion during ascending and descending stairs was significantly improved compared to 18-24 months after surgery (both P<0.01).
INTERPRETATION: The finding that functional knee motion continues to improve between 18-24 months and seven years post-surgery is of interest to both patients and those responsible for their treatment planning. Further, it was shown that the WOMAC and Knee Society Scores do not follow the same trends as the patients' functional knee kinematics seven years after total knee replacement surgery.

Entities:  

Mesh:

Year:  2007        PMID: 17275150     DOI: 10.1016/j.clinbiomech.2006.12.005

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  5 in total

1.  Actual knee motion during continuous passive motion protocols is less than expected.

Authors:  Jesse E Bible; Andrew K Simpson; Debdut Biswas; Richard R Pelker; Jonathan N Grauer
Journal:  Clin Orthop Relat Res       Date:  2009-02-27       Impact factor: 4.176

Review 2.  Risk of falls in patients with knee osteoarthritis undergoing total knee arthroplasty: A systematic review and best evidence synthesis.

Authors:  Giorgio di Laura Frattura; Giuseppe Filardo; Dario Giunchi; Augusto Fusco; Stefano Zaffagnini; Christian Candrian
Journal:  J Orthop       Date:  2018-08-24

Review 3.  The effect of total knee arthroplasty on patients' balance and incidence of falls: a systematic review.

Authors:  M Moutzouri; N Gleeson; E Billis; E Tsepis; I Panoutsopoulou; J Gliatis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-19       Impact factor: 4.342

4.  Temporal patterns of commonly used clinical outcome scales during a 5-year period after total knee arthroplasty.

Authors:  Vivek Tiwari; Jonggeun Lee; Gaurav Sharma; Yeon Gwi Kang; Tae Kyun Kim
Journal:  J Orthop Traumatol       Date:  2019-03-25

5.  The effects of total knee arthroplasty on knee proprioception of patients with knee osteoarthritis: a meta-analysis.

Authors:  Ya-Yue Xue; Jing-Nan Shi; Kuan Zhang; Hao-Hua Zhang; Song-Hua Yan
Journal:  J Orthop Surg Res       Date:  2022-05-07       Impact factor: 2.677

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.