Literature DB >> 1727342

Real-time sonography in ocular trauma.

J S Kwong1, P L Munk, D T Lin, A D Vellet, M Levin, A R Buckley.   

Abstract

Real-time sonography was evaluated retrospectively in 71 consecutive patients with ocular trauma. A total of 51 vitreous hemorrhages, 20 hemorrhages in the anterior chamber, 22 retinal detachments, seven choroidal detachments, five foreign bodies, and 12 dislocated lenses were identified sonographically. In 10 instances (three choroidal detachments, six retinal detachments, and one lens dislocation), these sonographic findings were not apparent on clinical examination. One hemorrhage of the anterior chamber was missed on sonography. Both sonography and clinical examination failed to visualize one retinal detachment. The results of this study show that real-time sonography is valuable in the assessment of ocular trauma and supplements clinical examination with valuable information.

Entities:  

Mesh:

Year:  1992        PMID: 1727342     DOI: 10.2214/ajr.158.1.1727342

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

Review 1.  Orbital sonography in children.

Authors:  F G Ramji; T L Slovis; J D Baker
Journal:  Pediatr Radiol       Date:  1996

2.  [Value of ultrasonography in eye injuries at Parakou (Benin)].

Authors:  Kofi-Mensa Savi de Tove; Abel Rodrigue Assavedo; Patricia Yekpe; Zakari Nikiema; Olivier Biaou; Vicentia Boco
Journal:  Pan Afr Med J       Date:  2013-07-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.