Literature DB >> 17272410

Effects of activation pattern on nonisometric human skeletal muscle performance.

Ryan D Maladen1, Ramu Perumal, Anthony S Wexler, Stuart A Binder-Macleod.   

Abstract

During volitional muscle activation, motor units often fire with varying discharge patterns that include brief, high-frequency bursts of activity. These variations in the activation rate allow the central nervous system to precisely control the forces produced by the muscle. The present study explores how varying the instantaneous frequency of stimulation pulses within a train affects nonisometric muscle performance. The peak excursion produced in response to each stimulation train was considered as the primary measure of muscle performance. The results showed that at each frequency tested between 10 and 50 Hz, variable-frequency trains that took advantage of the catchlike property of skeletal muscle produced greater excursions than constant-frequency trains. In addition, variable-frequency trains that could achieve targeted trajectories with fewer pulses than constant-frequency trains were identified. These findings suggest that similar to voluntary muscle activation patterns, varying the instantaneous frequency within a train of pulses can be used to improve muscle performance during functional electrical stimulation.

Entities:  

Mesh:

Year:  2007        PMID: 17272410     DOI: 10.1152/japplphysiol.00729.2006

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  10 in total

1.  Repetetive hindlimb movement using intermittent adaptive neuromuscular electrical stimulation in an incomplete spinal cord injury rodent model.

Authors:  Mallika D Fairchild; Seung-Jae Kim; Alex Iarkov; James J Abbas; Ranu Jung
Journal:  Exp Neurol       Date:  2010-03-03       Impact factor: 5.330

2.  Variable stimulation patterns in younger and older thenar muscle.

Authors:  Barbara M Doucet; Lisa Griffin
Journal:  J Electromyogr Kinesiol       Date:  2012-01-04       Impact factor: 2.368

Review 3.  Novel patterns of functional electrical stimulation have an immediate effect on dorsiflexor muscle function during gait for people poststroke.

Authors:  Trisha M Kesar; Ramu Perumal; Angela Jancosko; Darcy S Reisman; Katherine S Rudolph; Jill S Higginson; Stuart A Binder-Macleod
Journal:  Phys Ther       Date:  2009-11-19

4.  Neuromuscular stimulation therapy after incomplete spinal cord injury promotes recovery of interlimb coordination during locomotion.

Authors:  R Jung; A Belanger; T Kanchiku; M Fairchild; J J Abbas
Journal:  J Neural Eng       Date:  2009-09-01       Impact factor: 5.379

5.  Comparison of Proximally Versus Distally Placed Spatially Distributed Sequential Stimulation Electrodes in a Dynamic Knee Extension Task.

Authors:  Marco Laubacher; Efe A Aksöz; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Transl Myol       Date:  2016-06-13

6.  Effect of Stochastic Modulation of Inter-Pulse Interval During Stimulated Isokinetic Leg Extension.

Authors:  Efe Anil Aksöz; Marco Laubacher; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Transl Myol       Date:  2016-07-15

7.  Stochastically modulated inter-pulse intervals to increase the efficiency of functional electrical stimulation cycling.

Authors:  E A Aksöz; M A Luder; M Laubacher; R Riener; S A Binder-Macleod; K J Hunt
Journal:  J Rehabil Assist Technol Eng       Date:  2018-04-11

8.  Predicting non-isometric fatigue induced by electrical stimulation pulse trains as a function of pulse duration.

Authors:  M Susan Marion; Anthony S Wexler; Maury L Hull
Journal:  J Neuroeng Rehabil       Date:  2013-02-02       Impact factor: 4.262

Review 9.  Advances in selective activation of muscles for non-invasive motor neuroprostheses.

Authors:  Aikaterini D Koutsou; Juan C Moreno; Antonio J Del Ama; Eduardo Rocon; José L Pons
Journal:  J Neuroeng Rehabil       Date:  2016-06-13       Impact factor: 4.262

10.  Power output and fatigue properties using spatially distributed sequential stimulation in a dynamic knee extension task.

Authors:  Marco Laubacher; Anil Efe Aksöz; Robert Riener; Stuart Binder-Macleod; Kenneth J Hunt
Journal:  Eur J Appl Physiol       Date:  2017-07-03       Impact factor: 3.078

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.