Literature DB >> 17272034

Measurement of ocular torsion using digital fundus image.

J Seo1, K Kim, J Kim, K Park, H Chung.   

Abstract

Computer-based objective measurement of the ocular cyclotorsion using digital fundus photograph was developed. Color digital fundus photographs acquired with the field angle of 60 degrees , 1520 x 1080 in resolution were analyzed. Optic disc and macula were segmented by the program developed on MATLAB, which executed the serial analysis of the Otsu threshold, labeling, Canny edge. The angle between the horizontal line that bisects the optic disc and the line connecting the center of optic disc and macula was measured and compared with the torsion determined by the specialist. Optic disc and macula were segmented and the mean of the calculated angle was 3.02+/-1.24 degrees . The mean of the torsion determined by the specialist was 3.13+/-1.98 degrees and there was no difference between the two. The measurement of the cyclotorsion using computer program showed good coincidence with that of the specialist and it can be a good candidate as a tool helping precise diagnosis and the objective evaluation of the disease for the physicians.

Year:  2004        PMID: 17272034     DOI: 10.1109/IEMBS.2004.1403514

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  A Multi-Anatomical Retinal Structure Segmentation System for Automatic Eye Screening Using Morphological Adaptive Fuzzy Thresholding.

Authors:  Jasem Almotiri; Khaled Elleithy; Abdelrahman Elleithy
Journal:  IEEE J Transl Eng Health Med       Date:  2018-05-17       Impact factor: 3.316

2.  A new and effective method for human retina optic disc segmentation with fuzzy clustering method based on active contour model.

Authors:  Ahmad S Abdullah; Javad Rahebi; Yasa Ekşioğlu Özok; Mohanad Aljanabi
Journal:  Med Biol Eng Comput       Date:  2019-08-24       Impact factor: 2.602

3.  A novel method for retinal optic disc detection using bat meta-heuristic algorithm.

Authors:  Ahmad S Abdullah; Yasa Ekşioğlu Özok; Javad Rahebi
Journal:  Med Biol Eng Comput       Date:  2018-05-09       Impact factor: 2.602

4.  Measurement of ocular counter-roll using iris images during binocular fixation and head tilt.

Authors:  Kwang-Keun Oh; Byeong-Yeon Moon; Hyun Gug Cho; Sang-Yeob Kim; Dong-Sik Yu
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

5.  Automated measurement of the disc-fovea angle based on DeepLabv3.

Authors:  Bo Zheng; Yifan Shen; Yuxin Luo; Xinwen Fang; Shaojun Zhu; Jie Zhang; Maonian Wu; Ling Jin; Weihua Yang; Chenghu Wang
Journal:  Front Neurol       Date:  2022-07-27       Impact factor: 4.086

6.  Localization and segmentation of optic disc in retinal images using circular Hough transform and grow-cut algorithm.

Authors:  Muhammad Abdullah; Muhammad Moazam Fraz; Sarah A Barman
Journal:  PeerJ       Date:  2016-05-10       Impact factor: 2.984

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.