We present the development of operator and patient friendly conformal applicators that can deliver moderate temperature hyperthermia simultaneously with radiation in superficial tissue overlying contoured anatomy. This applicator combines the uniform heating capabilities of large area conformal microwave array (CMA) flexible printed circuit board applicators with a patient interface (coupling bolus) that facilitates positioning of brachytherapy sources at a fixed distance (e.g. 1.5 cm) from the skin. A customized inverse treatment planning program (IPSA) was used to optimize spacing of a parallel array of source catheters and separation distance from skin, and to characterize the effects of bolus thickness and conformal array curvature on radiation dose uniformity. Performance of a 15 cmx15 cm combination applicator was evaluated in flat and contoured homogenous muscle tissue models. Results demonstrate effective heating and radiation distributions to 1-1.5 cm depth and out to the periphery of the array. This applicator should prove useful for treatment of diffuse chestwall disease located over contoured anatomy that is difficult to treat with external beam radiation. By applying heat and radiation simultaneously for maximum synergism of modalities, this device should expand the number of patients that can benefit from effective thermoradiotherapy for superficial disease.

Entities:  

Year:  2004        PMID: 17270784     DOI: 10.1109/IEMBS.2004.1403724

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

2.  Vesicoureteral reflux in children: a phantom study of microwave heating and radiometric thermometry of pediatric bladder.

Authors:  Yngve Birkelund; Øystein Klemetsen; Svein K Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2011-09-06       Impact factor: 4.538

Review 3.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

4.  Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

Authors:  Kavitha Arunachalam; Oana I Craciunescu; Edward J Markewitz; Paolo F Maccarini; Jaime L Schlorff; Paul R Stauffer
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.