Literature DB >> 17270415

Array biosensor based on enzyme kinetics monitoring by fluorescence spectroscopy: application for neurotoxins detection.

M Ramanathan1, A L Simonian.   

Abstract

The aim of the present work is to develop an evanescence wave array biosensor exploiting the "kinetic" approach of enzymatic reaction and further detection of the reaction products via pH sensitive fluorophore reporter. To demonstrate the feasibility of this approach, we have developed a biosensor array with the potential for direct detection of organophosphates using as a biorecognition element, an enzyme organophosphorus hydrolase (OPH), conjugated with a pH-sensitive fluorophore, carboxynaphthofluorescein (CNF). The presence of reference spots allows the discrimination of the enzymatic and non-enzymatic based pH changes; bovine serum albumin (BSA) was used as a non-enzymatic scaffold protein for CNF attachment at the reference spots. An array biosensor unit developed at the Naval Research Laboratories (NRL) was adopted as the detection platform and appropriately modified for enzyme-based measurements. A planar multi-mode waveguide was covered with an optically transparent TiO(2) layer to increase the surface area available for immobilization. The biosensor enabled the detection of 2.5 microM paraoxon, and 10 microM DFP and parathion, respectively. Very short response time of 30s can be achieved with a total analysis time of less than 2 min. When operated at room temperature and stored at 4 degrees C, the waveguide retained reasonable activity for greater than 45 days.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17270415     DOI: 10.1016/j.bios.2006.12.029

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Monitoring of diisopropyl fluorophosphate hydrolysis by fluoride-selective polymeric films using absorbance spectroscopy.

Authors:  Madhumati Ramanathan; Lin Wang; James R Wild; Mark E Meyerhoff; Mark E Meyeroff; Aleksandr L Simonian
Journal:  Anal Chim Acta       Date:  2010-04-10       Impact factor: 6.558

2.  Development of fluorescent array based on sol-gel/chitosan encapsulated acetylcholinesterase and pH sensitive oxazol-5-one derivative.

Authors:  Gulsiye Ozturk; Karl-Heinz Feller; Kay Dornbusch; Suna Timur; Serap Alp; Yavuz Ergun
Journal:  J Fluoresc       Date:  2010-07-09       Impact factor: 2.217

Review 3.  Evanescent wave fluorescence biosensors: Advances of the last decade.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2015-07-20       Impact factor: 10.618

Review 4.  Fluorescence based fiber optic and planar waveguide biosensors. A review.

Authors:  Elena Benito-Peña; Mayra Granda Valdés; Bettina Glahn-Martínez; Maria C Moreno-Bondi
Journal:  Anal Chim Acta       Date:  2016-09-13       Impact factor: 6.558

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.