Literature DB >> 17267839

Nuchal translucency and the risk of congenital heart disease.

Lynn L Simpson1, Fergal D Malone, Diana W Bianchi, Robert H Ball, David A Nyberg, Christine H Comstock, George Saade, Keith Eddleman, Susan J Gross, Lorraine Dugoff, Sabrina D Craigo, Ilan E Timor-Tritsch, Stephen R Carr, Honor M Wolfe, Tara Tripp, Mary E D'Alton.   

Abstract

OBJECTIVE: To estimate whether nuchal translucency assessment is a useful screening tool for major congenital heart disease (CHD) in the absence of aneuploidy.
METHODS: Unselected patients with singleton pregnancies at 10(3/7) to 13(6/7) weeks of gestation were recruited at 15 U.S. centers to undergo nuchal translucency sonography. Screening characteristics of nuchal translucency in the detection of major CHD were determined using different cutoffs (2.0 or more multiples of the median [MoM], 2.5 or more MoM, 3.0 or more MoM).
RESULTS: A total of 34,266 euploid fetuses with cardiac outcome data were available for analysis. There were 224 cases of CHD (incidence 6.5 per 1,000), of which 52 (23.2%) were major (incidence 1.5 per 1,000). The incidence of major CHD increased with increasing nuchal translucency: 14.1 per 1,000, 33.5 per 1,000, and 49.5 per 1,000 at 2.0 or more MoM, 2.5 or more MoM, and 3.0 or more MoM cutoffs, respectively. Sensitivity, specificity, and positive predictive values were 15.4%, 98.4%, and 1.4% at 2.0 or more MoM; 13.5%, 99.4%, and 3.3% at 2.5 or more MoM; and 9.6%, 99.7%, and 5.0% at 3.0 or more MoM. Nuchal translucency of 2.5 or more MoM (99th percentile) had a likelihood ratio (95% confidence interval) of 22.5 (11.4-45.5) for major CHD. Based on our data, for every 100 patients referred for fetal echocardiography with a nuchal translucency of 99th percentile or more, three will have a major cardiac anomaly.
CONCLUSION: Nuchal translucency sonography in the first trimester lacks the characteristics of a good screening tool for major CHD in a large unselected population. However, nuchal translucency of 2.5 or more MoM (99th percentile or more) should be considered an indication for fetal echocardiography. LEVEL OF EVIDENCE: II.

Entities:  

Mesh:

Year:  2007        PMID: 17267839     DOI: 10.1097/01.AOG.0000250473.99575.72

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  9 in total

1.  Early fetal echocardiography: ready for prime time?

Authors:  Fadi G Mirza; Samuel T Bauer; Ismee A Williams; Lynn L Simpson
Journal:  Am J Perinatol       Date:  2011-12-05       Impact factor: 1.862

2.  Advances in ultrasound imaging for congenital malformations during early gestation.

Authors:  William F Rayburn; Jennifer A Jolley; Lynn L Simpson
Journal:  Birth Defects Res A Clin Mol Teratol       Date:  2015-03-28

Review 3.  Adverse pregnancy outcomes after abnormal first-trimester screening for aneuploidy.

Authors:  Laura Goetzl
Journal:  Clin Lab Med       Date:  2010-09       Impact factor: 1.935

Review 4.  Obstetric management, tests, and technologies that impact childhood development.

Authors:  Christopher M Novak; Ernest M Graham
Journal:  Dev Med Child Neurol       Date:  2019-01-28       Impact factor: 5.449

5.  The clinical practice patterns of fetal ultrasonography in the first-trimester: A questionnaire survey of members of the Korean Society of Ultrasound in Obstetrics and Gynecology.

Authors:  Kun Woo Kim; Dong Wook Kwak; Hyun Sun Ko; Hyun Soo Park; Hyun Joo Seol; Joon Seok Hong; Seung Woo Yang; Han Sung Hwang; Soo Young Oh; Moon Young Kim; Sa Jin Kim
Journal:  Obstet Gynecol Sci       Date:  2014-11-20

6.  Brazilian Fetal Cardiology Guidelines - 2019.

Authors:  Simone R F Fontes Pedra; Paulo Zielinsky; Cristiane Nogueira Binotto; Cristiane Nunes Martins; Eduardo Sérgio Valério Borges da Fonseca; Isabel Cristina Britto Guimarães; Izabele Vian da Silveira Corrêa; Karla Luiza Matos Pedrosa; Lilian Maria Lopes; Luiz Henrique Soares Nicoloso; Marcia Ferreira Alves Barberato; Marina Maccagnano Zamith
Journal:  Arq Bras Cardiol       Date:  2019-06-06       Impact factor: 2.000

Review 7.  The current state of prenatal detection of genetic conditions in congenital heart defects.

Authors:  Tina O Findley; Hope Northrup
Journal:  Transl Pediatr       Date:  2021-08

8.  The Mathematical Limitations of Fetal Echocardiography as a Screening Tool in the Setting of a Normal Second-Trimester Ultrasound.

Authors:  Samuel Bellavance; Mikhail-Paul Cardinal; Laurence Gobeil; Marie-Eve Roy-Lacroix; Frédéric Dallaire
Journal:  CJC Open       Date:  2021-06-18

Review 9.  Prenatal Screening Using Maternal Markers.

Authors:  Howard Cuckle
Journal:  J Clin Med       Date:  2014-05-09       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.